Frame 000000 [2009-08-25 10:46:18:037] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 A2 0C 0C 02 3F FF FF 19 61 36 DC Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000001 [2009-08-25 10:46:18:196] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 1A D4 01 0C 57 4C 01 32 00 03 A3 0F 0C 00 40 00 66 19 55 3E 44 00 00 00 00 3F 49 10 AE 4C Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (102), Property ID: present_value Frame 000002 [2009-08-25 10:46:19:359] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 0A 00 01 20 57 4C 01 32 FF 20 A3 0F 86 11 Pdu: simple_ack_pdu Frame 000003 [2009-08-25 10:46:19:511] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 A4 0C 0C 02 3F FF FF 19 61 29 78 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000004 [2009-08-25 10:46:19:664] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 A2 0C 91 01 91 1F 93 0D Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000005 [2009-08-25 10:46:19:818] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 A4 0C 91 01 91 1F 69 15 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000006 [2009-08-25 10:46:19:973] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 1A D4 01 0C 57 4C 01 32 00 03 A5 0F 0C 00 40 00 68 19 55 3E 44 00 00 00 00 3F 49 10 FF 43 Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (104), Property ID: present_value Frame 000007 [2009-08-25 10:46:19:128] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 0A 00 01 20 57 4C 01 32 FF 20 A5 0F 56 45 Pdu: simple_ack_pdu Frame 000008 [2009-08-25 10:46:20:282] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 A6 0C 0C 02 3F FF FF 19 61 D3 E3 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000009 [2009-08-25 10:46:20:443] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 A6 0C 91 01 91 1F 3F 1D Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000010 [2009-08-25 10:46:20:599] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 A7 0C 0C 00 00 00 F1 19 55 3B BA Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (241), Property ID: present_value Frame 000011 [2009-08-25 10:46:20:755] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 A7 0C 0C 00 00 00 F1 19 55 3E 44 00 00 00 00 3F E7 D4 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (241), Property ID: present_value, Property Value: 0.000 Frame 000012 [2009-08-25 10:46:20:912] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 A8 0C 0C 00 C0 00 64 19 55 A0 D7 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Binary input (100), Property ID: present_value Frame 000013 [2009-08-25 10:46:20:080] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 15 F4 01 20 57 4C 01 32 FF 30 A8 0C 0C 00 C0 00 64 19 55 3E 91 01 3F 9F 3A Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Binary input (100), Property ID: present_value, Property Value: 1 Frame 000014 [2009-08-25 10:46:20:236] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 A9 0C 0C 02 3F FF FF 19 61 FB 75 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000015 [2009-08-25 10:46:21:392] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 A9 0C 91 01 91 1F B6 20 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000016 [2009-08-25 10:46:21:549] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 AA 0C 0C 00 00 00 F4 19 55 54 8E Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (244), Property ID: present_value Frame 000017 [2009-08-25 10:46:21:706] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 AA 0C 0C 00 00 00 F4 19 55 3E 44 43 7F 00 00 3F B8 8A Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (244), Property ID: present_value, Property Value: 255.000 Frame 000018 [2009-08-25 10:46:21:863] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 AB 0C 0C 02 3F FF FF 19 61 01 EE Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000019 [2009-08-25 10:46:21:020] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 AB 0C 91 01 91 1F E0 28 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000020 [2009-08-25 10:46:21:178] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 AC 0C 0C 00 00 01 1D 19 55 4F A3 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (285), Property ID: present_value Frame 000021 [2009-08-25 10:46:22:336] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 AC 0C 0C 00 00 01 1D 19 55 3E 44 43 7F 00 00 3F 4C F9 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (285), Property ID: present_value, Property Value: 255.000 Frame 000022 [2009-08-25 10:46:22:495] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 AD 0C 0C 02 3F FF FF 19 61 1E 4A Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000023 [2009-08-25 10:46:22:653] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 AD 0C 91 01 91 1F 1A 30 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000024 [2009-08-25 10:46:22:810] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 AE 0C 0C 00 00 00 F5 19 55 6D EB Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (245), Property ID: present_value Frame 000025 [2009-08-25 10:46:22:967] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 AE 0C 0C 00 00 00 F5 19 55 3E 44 00 00 00 00 3F AF BA Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (245), Property ID: present_value, Property Value: 0.000 Frame 000026 [2009-08-25 10:46:22:979] S_MAC-50 D_MAC-77 Poll For Master /Valid 55 FF 01 4D 32 00 00 28 Frame 000027 [2009-08-25 10:46:22:991] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000028 [2009-08-25 10:46:22:002] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000029 [2009-08-25 10:46:22:014] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000030 [2009-08-25 10:46:22:026] S_MAC-11 D_MAC-19 Poll For Master /Valid 55 FF 01 13 0B 00 00 0B Frame 000031 [2009-08-25 10:46:22:038] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000032 [2009-08-25 10:46:22:201] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 AF 0C 0C 02 3F FF FF 19 61 E4 D1 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000033 [2009-08-25 10:46:23:359] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 AF 0C 91 01 91 1F 4C 38 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000034 [2009-08-25 10:46:23:371] S_MAC-50 D_MAC-78 Poll For Master /Valid 55 FF 01 4E 32 00 00 B0 Frame 000035 [2009-08-25 10:46:23:382] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000036 [2009-08-25 10:46:23:394] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000037 [2009-08-25 10:46:23:406] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000038 [2009-08-25 10:46:23:418] S_MAC-11 D_MAC-20 Poll For Master /Valid 55 FF 01 14 0B 00 00 B1 Frame 000039 [2009-08-25 10:46:23:430] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000040 [2009-08-25 10:46:23:586] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B0 0C 0C 00 00 00 F7 19 55 94 7A Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (247), Property ID: present_value Frame 000041 [2009-08-25 10:46:23:744] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B0 0C 0C 00 00 00 F7 19 55 3E 44 42 C8 00 00 3F 55 26 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (247), Property ID: present_value, Property Value: 100.000 Frame 000042 [2009-08-25 10:46:23:757] S_MAC-50 D_MAC-79 Poll For Master /Valid 55 FF 01 4F 32 00 00 39 Frame 000043 [2009-08-25 10:46:23:768] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000044 [2009-08-25 10:46:23:780] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000045 [2009-08-25 10:46:23:792] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000046 [2009-08-25 10:46:23:803] S_MAC-11 D_MAC-21 Poll For Master /Valid 55 FF 01 15 0B 00 00 38 Frame 000047 [2009-08-25 10:46:23:815] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000048 [2009-08-25 10:46:23:973] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 B1 0C 0C 02 3F FF FF 19 61 A5 F5 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000049 [2009-08-25 10:46:23:132] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 B1 0C 91 01 91 1F 5E 43 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000050 [2009-08-25 10:46:23:144] S_MAC-50 D_MAC-80 Poll For Master /Valid 55 FF 01 50 32 00 00 4F Frame 000051 [2009-08-25 10:46:23:156] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000052 [2009-08-25 10:46:23:168] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000053 [2009-08-25 10:46:23:180] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000054 [2009-08-25 10:46:23:192] S_MAC-11 D_MAC-22 Poll For Master /Valid 55 FF 01 16 0B 00 00 A0 Frame 000055 [2009-08-25 10:46:23:204] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000056 [2009-08-25 10:46:24:361] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B2 0C 0C 00 00 00 FA 19 55 11 1E Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (250), Property ID: present_value Frame 000057 [2009-08-25 10:46:24:519] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B2 0C 0C 00 00 00 FA 19 55 3E 44 3F 80 00 00 3F 1E 5D Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (250), Property ID: present_value, Property Value: 1.000 Frame 000058 [2009-08-25 10:46:24:532] S_MAC-50 D_MAC-81 Poll For Master /Valid 55 FF 01 51 32 00 00 C6 Frame 000059 [2009-08-25 10:46:24:543] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000060 [2009-08-25 10:46:24:555] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000061 [2009-08-25 10:46:24:568] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000062 [2009-08-25 10:46:24:580] S_MAC-11 D_MAC-23 Poll For Master /Valid 55 FF 01 17 0B 00 00 29 Frame 000063 [2009-08-25 10:46:24:591] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000064 [2009-08-25 10:46:24:756] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 B3 0C 0C 02 3F FF FF 19 61 5F 6E Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000065 [2009-08-25 10:46:24:915] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 B3 0C 91 01 91 1F 08 4B Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000066 [2009-08-25 10:46:24:928] S_MAC-50 D_MAC-82 Poll For Master /Valid 55 FF 01 52 32 00 00 5E Frame 000067 [2009-08-25 10:46:24:940] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000068 [2009-08-25 10:46:24:952] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000069 [2009-08-25 10:46:24:964] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000070 [2009-08-25 10:46:24:976] S_MAC-11 D_MAC-24 Poll For Master /Valid 55 FF 01 18 0B 00 00 D7 Frame 000071 [2009-08-25 10:46:24:988] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000072 [2009-08-25 10:46:24:148] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B4 0C 0C 00 00 00 FE 19 55 6F D9 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (254), Property ID: present_value Frame 000073 [2009-08-25 10:46:25:306] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B4 0C 0C 00 00 00 FE 19 55 3E 44 41 30 00 00 3F 06 C4 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (254), Property ID: present_value, Property Value: 11.000 Frame 000074 [2009-08-25 10:46:25:319] S_MAC-50 D_MAC-83 Poll For Master /Valid 55 FF 01 53 32 00 00 D7 Frame 000075 [2009-08-25 10:46:25:331] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000076 [2009-08-25 10:46:25:343] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000077 [2009-08-25 10:46:25:355] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000078 [2009-08-25 10:46:25:367] S_MAC-11 D_MAC-25 Poll For Master /Valid 55 FF 01 19 0B 00 00 5E Frame 000079 [2009-08-25 10:46:25:379] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000080 [2009-08-25 10:46:25:537] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 B5 0C 0C 02 3F FF FF 19 61 40 CA Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000081 [2009-08-25 10:46:25:694] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 B5 0C 91 01 91 1F F2 53 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000082 [2009-08-25 10:46:25:707] S_MAC-50 D_MAC-84 Poll For Master /Valid 55 FF 01 54 32 00 00 6D Frame 000083 [2009-08-25 10:46:25:718] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000084 [2009-08-25 10:46:25:731] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000085 [2009-08-25 10:46:25:742] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000086 [2009-08-25 10:46:25:754] S_MAC-11 D_MAC-26 Poll For Master /Valid 55 FF 01 1A 0B 00 00 C6 Frame 000087 [2009-08-25 10:46:25:766] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000088 [2009-08-25 10:46:25:922] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B6 0C 0C 00 00 00 FD 19 55 F1 AD Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (253), Property ID: present_value Frame 000089 [2009-08-25 10:46:25:080] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B6 0C 0C 00 00 00 FD 19 55 3E 44 00 00 00 00 3F CA 22 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (253), Property ID: present_value, Property Value: 0.000 Frame 000090 [2009-08-25 10:46:25:093] S_MAC-50 D_MAC-85 Poll For Master /Valid 55 FF 01 55 32 00 00 E4 Frame 000091 [2009-08-25 10:46:25:105] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000092 [2009-08-25 10:46:25:117] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000093 [2009-08-25 10:46:25:129] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000094 [2009-08-25 10:46:25:141] S_MAC-11 D_MAC-27 Poll For Master /Valid 55 FF 01 1B 0B 00 00 4F Frame 000095 [2009-08-25 10:46:25:153] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000096 [2009-08-25 10:46:26:310] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 B7 0C 0C 02 3F FF FF 19 61 BA 51 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000097 [2009-08-25 10:46:26:466] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 B7 0C 91 01 91 1F A4 5B Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000098 [2009-08-25 10:46:26:479] S_MAC-50 D_MAC-86 Poll For Master /Valid 55 FF 01 56 32 00 00 7C Frame 000099 [2009-08-25 10:46:26:491] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000100 [2009-08-25 10:46:26:503] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000101 [2009-08-25 10:46:26:515] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000102 [2009-08-25 10:46:26:527] S_MAC-11 D_MAC-28 Poll For Master /Valid 55 FF 01 1C 0B 00 00 F5 Frame 000103 [2009-08-25 10:46:26:539] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000104 [2009-08-25 10:46:26:697] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B8 0C 0C 00 00 00 E8 19 55 0C CA Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (232), Property ID: present_value Frame 000105 [2009-08-25 10:46:26:854] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B8 0C 0C 00 00 00 E8 19 55 3E 44 40 40 00 00 3F 21 D7 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (232), Property ID: present_value, Property Value: 3.000 Frame 000106 [2009-08-25 10:46:26:866] S_MAC-50 D_MAC-87 Poll For Master /Valid 55 FF 01 57 32 00 00 F5 Frame 000107 [2009-08-25 10:46:26:878] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000108 [2009-08-25 10:46:26:890] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000109 [2009-08-25 10:46:26:912] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000110 [2009-08-25 10:46:26:924] S_MAC-11 D_MAC-29 Poll For Master /Valid 55 FF 01 1D 0B 00 00 7C Frame 000111 [2009-08-25 10:46:26:936] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000112 [2009-08-25 10:46:26:094] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 B9 0C 0C 00 00 00 F2 19 55 1E 71 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (242), Property ID: present_value Frame 000113 [2009-08-25 10:46:26:254] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 B9 0C 0C 00 00 00 F2 19 55 3E 44 42 B3 2B 02 3F 47 E7 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (242), Property ID: present_value, Property Value: 89.584 Frame 000114 [2009-08-25 10:46:26:266] S_MAC-50 D_MAC-88 Poll For Master /Valid 55 FF 01 58 32 00 00 0B Frame 000115 [2009-08-25 10:46:27:278] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000116 [2009-08-25 10:46:27:290] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000117 [2009-08-25 10:46:27:302] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000118 [2009-08-25 10:46:27:314] S_MAC-11 D_MAC-30 Poll For Master /Valid 55 FF 01 1E 0B 00 00 E4 Frame 000119 [2009-08-25 10:46:27:326] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000120 [2009-08-25 10:46:27:484] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 BA 0C 0C 02 3F FF FF 19 61 68 5C Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000121 [2009-08-25 10:46:27:641] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 BA 0C 91 01 91 1F 7B 6E Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000122 [2009-08-25 10:46:27:679] S_MAC-50 D_MAC-89 Poll For Master /Valid 55 FF 01 59 32 00 00 82 Frame 000123 [2009-08-25 10:46:27:691] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000124 [2009-08-25 10:46:27:703] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000125 [2009-08-25 10:46:27:715] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000126 [2009-08-25 10:46:27:727] S_MAC-11 D_MAC-31 Poll For Master /Valid 55 FF 01 1F 0B 00 00 6D Frame 000127 [2009-08-25 10:46:27:739] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000128 [2009-08-25 10:46:27:897] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 BB 0C 0C 00 00 00 F0 19 55 5C 5F Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (240), Property ID: present_value Frame 000129 [2009-08-25 10:46:27:055] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 BB 0C 0C 00 00 00 F0 19 55 3E 44 42 5C 65 2C 3F 05 02 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (240), Property ID: present_value, Property Value: 55.099 Frame 000130 [2009-08-25 10:46:27:068] S_MAC-50 D_MAC-90 Poll For Master /Valid 55 FF 01 5A 32 00 00 1A Frame 000131 [2009-08-25 10:46:27:080] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000132 [2009-08-25 10:46:27:092] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000133 [2009-08-25 10:46:27:105] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000134 [2009-08-25 10:46:27:117] S_MAC-11 D_MAC-32 Poll For Master /Valid 55 FF 01 20 0B 00 00 08 Frame 000135 [2009-08-25 10:46:27:129] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000136 [2009-08-25 10:46:28:286] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 BC 0C 0C 02 3F FF FF 19 61 77 F8 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000137 [2009-08-25 10:46:28:444] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 BC 0C 91 01 91 1F 81 76 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000138 [2009-08-25 10:46:28:456] S_MAC-50 D_MAC-91 Poll For Master /Valid 55 FF 01 5B 32 00 00 93 Frame 000139 [2009-08-25 10:46:28:468] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000140 [2009-08-25 10:46:28:480] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000141 [2009-08-25 10:46:28:493] S_MAC-7 D_MAC-8 Poll For Master /Valid 55 FF 01 08 07 00 00 F5 Frame 000142 [2009-08-25 10:46:28:505] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000143 [2009-08-25 10:46:28:517] S_MAC-11 D_MAC-33 Poll For Master /Valid 55 FF 01 21 0B 00 00 81 Frame 000144 [2009-08-25 10:46:28:529] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000145 [2009-08-25 10:46:28:687] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 BD 0C 0C 00 00 01 19 19 55 47 72 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (281), Property ID: present_value Frame 000146 [2009-08-25 10:46:28:844] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 BD 0C 0C 00 00 01 19 19 55 3E 44 42 A0 75 5A 3F 6F B0 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (281), Property ID: present_value, Property Value: 80.229 Frame 000147 [2009-08-25 10:46:28:857] S_MAC-50 D_MAC-92 Poll For Master /Valid 55 FF 01 5C 32 00 00 29 Frame 000148 [2009-08-25 10:46:28:869] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000149 [2009-08-25 10:46:28:881] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000150 [2009-08-25 10:46:28:893] S_MAC-7 D_MAC-9 Poll For Master /Valid 55 FF 01 09 07 00 00 7C Frame 000151 [2009-08-25 10:46:28:905] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000152 [2009-08-25 10:46:28:917] S_MAC-11 D_MAC-34 Poll For Master /Valid 55 FF 01 22 0B 00 00 19 Frame 000153 [2009-08-25 10:46:28:930] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000154 [2009-08-25 10:46:28:088] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 BE 0C 0C 02 3F FF FF 19 61 8D 63 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000155 [2009-08-25 10:46:28:247] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 BE 0C 91 01 91 1F D7 7E Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000156 [2009-08-25 10:46:28:260] S_MAC-50 D_MAC-93 Poll For Master /Valid 55 FF 01 5D 32 00 00 A0 Frame 000157 [2009-08-25 10:46:28:272] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000158 [2009-08-25 10:46:29:284] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000159 [2009-08-25 10:46:29:296] S_MAC-7 D_MAC-10 Poll For Master /Valid 55 FF 01 0A 07 00 00 E4 Frame 000160 [2009-08-25 10:46:29:308] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000161 [2009-08-25 10:46:29:321] S_MAC-11 D_MAC-35 Poll For Master /Valid 55 FF 01 23 0B 00 00 90 Frame 000162 [2009-08-25 10:46:29:333] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000163 [2009-08-25 10:46:29:491] S_MAC-50 D_MAC-11 Data Expecting Reply /Valid 55 FF 05 0B 32 00 11 2C 01 0C 57 4C 01 32 00 03 BF 0C 0C 00 00 00 F3 19 55 DD 8F Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (243), Property ID: present_value Frame 000164 [2009-08-25 10:46:29:649] S_MAC-11 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 0B 00 18 0E 01 20 57 4C 01 32 FF 30 BF 0C 0C 00 00 00 F3 19 55 3E 44 42 A0 80 00 3F 9E 04 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (243), Property ID: present_value, Property Value: 80.250 Frame 000165 [2009-08-25 10:46:29:661] S_MAC-50 D_MAC-94 Poll For Master /Valid 55 FF 01 5E 32 00 00 38 Frame 000166 [2009-08-25 10:46:29:674] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000167 [2009-08-25 10:46:29:686] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000168 [2009-08-25 10:46:29:698] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000169 [2009-08-25 10:46:29:710] S_MAC-11 D_MAC-36 Poll For Master /Valid 55 FF 01 24 0B 00 00 2A Frame 000170 [2009-08-25 10:46:29:723] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000171 [2009-08-25 10:46:29:735] S_MAC-50 D_MAC-95 Poll For Master /Valid 55 FF 01 5F 32 00 00 B1 Frame 000172 [2009-08-25 10:46:29:748] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000173 [2009-08-25 10:46:29:760] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000174 [2009-08-25 10:46:29:772] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000175 [2009-08-25 10:46:29:784] S_MAC-11 D_MAC-37 Poll For Master /Valid 55 FF 01 25 0B 00 00 A3 Frame 000176 [2009-08-25 10:46:29:796] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000177 [2009-08-25 10:46:29:953] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 00 0C 0C 02 3F FF FF 19 61 22 74 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000178 [2009-08-25 10:46:29:112] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 00 0C 91 01 91 1F 07 85 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000179 [2009-08-25 10:46:29:124] S_MAC-50 D_MAC-96 Poll For Master /Valid 55 FF 01 60 32 00 00 D4 Frame 000180 [2009-08-25 10:46:29:137] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000181 [2009-08-25 10:46:29:149] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000182 [2009-08-25 10:46:29:161] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000183 [2009-08-25 10:46:29:173] S_MAC-11 D_MAC-38 Poll For Master /Valid 55 FF 01 26 0B 00 00 3B Frame 000184 [2009-08-25 10:46:29:185] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000185 [2009-08-25 10:46:30:344] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 1A A3 01 0C 57 4C 01 32 00 03 01 0F 0C 00 40 00 65 19 55 3E 44 43 51 00 00 3F 49 10 BD 70 Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (101), Property ID: present_value Frame 000186 [2009-08-25 10:46:30:501] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0A 99 01 20 57 4C 01 32 FF 20 01 0F C9 8D Pdu: simple_ack_pdu Frame 000187 [2009-08-25 10:46:30:513] S_MAC-50 D_MAC-97 Poll For Master /Valid 55 FF 01 61 32 00 00 5D Frame 000188 [2009-08-25 10:46:30:526] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000189 [2009-08-25 10:46:30:538] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000190 [2009-08-25 10:46:30:550] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000191 [2009-08-25 10:46:30:562] S_MAC-11 D_MAC-39 Poll For Master /Valid 55 FF 01 27 0B 00 00 B2 Frame 000192 [2009-08-25 10:46:30:610] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000193 [2009-08-25 10:46:30:766] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 02 0C 0C 02 3F FF FF 19 61 D8 EF Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000194 [2009-08-25 10:46:30:923] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 02 0C 91 01 91 1F 51 8D Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000195 [2009-08-25 10:46:30:935] S_MAC-50 D_MAC-98 Poll For Master /Valid 55 FF 01 62 32 00 00 C5 Frame 000196 [2009-08-25 10:46:30:948] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000197 [2009-08-25 10:46:30:960] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000198 [2009-08-25 10:46:30:972] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000199 [2009-08-25 10:46:30:984] S_MAC-11 D_MAC-40 Poll For Master /Valid 55 FF 01 28 0B 00 00 4C Frame 000200 [2009-08-25 10:46:30:996] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000201 [2009-08-25 10:46:30:156] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 1A A3 01 0C 57 4C 01 32 00 03 03 0F 0C 00 40 00 66 19 55 3E 44 00 00 00 00 3F 49 10 AE 25 Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (102), Property ID: present_value Frame 000202 [2009-08-25 10:46:31:313] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0A 99 01 20 57 4C 01 32 FF 20 03 0F 79 BE Pdu: simple_ack_pdu Frame 000203 [2009-08-25 10:46:31:325] S_MAC-50 D_MAC-99 Poll For Master /Valid 55 FF 01 63 32 00 00 4C Frame 000204 [2009-08-25 10:46:31:337] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000205 [2009-08-25 10:46:31:349] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000206 [2009-08-25 10:46:31:361] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000207 [2009-08-25 10:46:31:373] S_MAC-11 D_MAC-41 Poll For Master /Valid 55 FF 01 29 0B 00 00 C5 Frame 000208 [2009-08-25 10:46:31:385] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000209 [2009-08-25 10:46:31:545] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 04 0C 0C 02 3F FF FF 19 61 C7 4B Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000210 [2009-08-25 10:46:31:702] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 04 0C 91 01 91 1F AB 95 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000211 [2009-08-25 10:46:31:715] S_MAC-50 D_MAC-100 Poll For Master /Valid 55 FF 01 64 32 00 00 F6 Frame 000212 [2009-08-25 10:46:31:727] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000213 [2009-08-25 10:46:31:739] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000214 [2009-08-25 10:46:31:751] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000215 [2009-08-25 10:46:31:763] S_MAC-11 D_MAC-42 Poll For Master /Valid 55 FF 01 2A 0B 00 00 5D Frame 000216 [2009-08-25 10:46:31:775] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000217 [2009-08-25 10:46:31:932] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 1A A3 01 0C 57 4C 01 32 00 03 05 0F 0C 00 40 00 73 19 55 3E 44 42 44 00 00 3F 49 10 E5 50 Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (115), Property ID: present_value Frame 000218 [2009-08-25 10:46:31:089] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0A 99 01 20 57 4C 01 32 FF 20 05 0F A9 EA Pdu: simple_ack_pdu Frame 000219 [2009-08-25 10:46:31:102] S_MAC-50 D_MAC-101 Poll For Master /Valid 55 FF 01 65 32 00 00 7F Frame 000220 [2009-08-25 10:46:31:114] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000221 [2009-08-25 10:46:31:127] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000222 [2009-08-25 10:46:31:139] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000223 [2009-08-25 10:46:31:152] S_MAC-11 D_MAC-43 Poll For Master /Valid 55 FF 01 2B 0B 00 00 D4 Frame 000224 [2009-08-25 10:46:31:164] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000225 [2009-08-25 10:46:32:322] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 06 0C 0C 02 3F FF FF 19 61 3D D0 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000226 [2009-08-25 10:46:32:479] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 06 0C 91 01 91 1F FD 9D Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000227 [2009-08-25 10:46:32:492] S_MAC-50 D_MAC-102 Poll For Master /Valid 55 FF 01 66 32 00 00 E7 Frame 000228 [2009-08-25 10:46:32:504] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000229 [2009-08-25 10:46:32:516] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000230 [2009-08-25 10:46:32:528] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000231 [2009-08-25 10:46:32:541] S_MAC-11 D_MAC-44 Poll For Master /Valid 55 FF 01 2C 0B 00 00 6E Frame 000232 [2009-08-25 10:46:32:553] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000233 [2009-08-25 10:46:32:712] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 1A A3 01 0C 57 4C 01 32 00 03 07 0F 0C 00 40 00 68 19 55 3E 44 00 00 00 00 3F 49 10 20 D3 Pdu: confirmed_request_pdu, Type: write_property_request Object ID: Analog output (104), Property ID: present_value Frame 000234 [2009-08-25 10:46:32:868] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0A 99 01 20 57 4C 01 32 FF 20 07 0F 19 D9 Pdu: simple_ack_pdu Frame 000235 [2009-08-25 10:46:32:880] S_MAC-50 D_MAC-103 Poll For Master /Valid 55 FF 01 67 32 00 00 6E Frame 000236 [2009-08-25 10:46:32:892] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000237 [2009-08-25 10:46:32:904] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000238 [2009-08-25 10:46:32:917] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000239 [2009-08-25 10:46:32:929] S_MAC-11 D_MAC-45 Poll For Master /Valid 55 FF 01 2D 0B 00 00 E7 Frame 000240 [2009-08-25 10:46:32:942] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000241 [2009-08-25 10:46:32:100] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 08 0C 0C 02 3F FF FF 19 61 E8 0B Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000242 [2009-08-25 10:46:32:258] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 08 0C 91 01 91 1F 5F A4 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000243 [2009-08-25 10:46:32:270] S_MAC-50 D_MAC-104 Poll For Master /Valid 55 FF 01 68 32 00 00 90 Frame 000244 [2009-08-25 10:46:33:282] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000245 [2009-08-25 10:46:33:294] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000246 [2009-08-25 10:46:33:306] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000247 [2009-08-25 10:46:33:318] S_MAC-11 D_MAC-46 Poll For Master /Valid 55 FF 01 2E 0B 00 00 7F Frame 000248 [2009-08-25 10:46:33:331] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000249 [2009-08-25 10:46:33:490] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 09 0C 0C 00 00 00 F1 19 55 00 52 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (241), Property ID: present_value Frame 000250 [2009-08-25 10:46:33:663] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 09 0C 0C 00 00 00 F1 19 55 3E 44 00 00 00 00 3F 64 D7 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (241), Property ID: present_value, Property Value: 0.000 Frame 000251 [2009-08-25 10:46:33:675] S_MAC-50 D_MAC-105 Poll For Master /Valid 55 FF 01 69 32 00 00 19 Frame 000252 [2009-08-25 10:46:33:687] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000253 [2009-08-25 10:46:33:699] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000254 [2009-08-25 10:46:33:712] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000255 [2009-08-25 10:46:33:724] S_MAC-11 D_MAC-47 Poll For Master /Valid 55 FF 01 2F 0B 00 00 F6 Frame 000256 [2009-08-25 10:46:33:736] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000257 [2009-08-25 10:46:33:893] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0A 0C 0C 00 C0 00 64 19 55 B4 7F Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Binary input (100), Property ID: present_value Frame 000258 [2009-08-25 10:46:33:061] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 15 6D 01 20 57 4C 01 32 FF 30 0A 0C 0C 00 C0 00 64 19 55 3E 91 01 3F C7 42 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Binary input (100), Property ID: present_value, Property Value: 1 Frame 000259 [2009-08-25 10:46:33:073] S_MAC-50 D_MAC-106 Poll For Master /Valid 55 FF 01 6A 32 00 00 81 Frame 000260 [2009-08-25 10:46:33:086] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000261 [2009-08-25 10:46:33:099] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000262 [2009-08-25 10:46:33:111] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000263 [2009-08-25 10:46:33:123] S_MAC-11 D_MAC-48 Poll For Master /Valid 55 FF 01 30 0B 00 00 80 Frame 000264 [2009-08-25 10:46:33:137] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000265 [2009-08-25 10:46:34:295] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0B 0C 0C 02 3F FF FF 19 61 EF DD Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000266 [2009-08-25 10:46:34:454] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 0B 0C 91 01 91 1F 22 A8 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000267 [2009-08-25 10:46:34:466] S_MAC-50 D_MAC-107 Poll For Master /Valid 55 FF 01 6B 32 00 00 08 Frame 000268 [2009-08-25 10:46:34:478] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000269 [2009-08-25 10:46:34:490] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000270 [2009-08-25 10:46:34:503] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000271 [2009-08-25 10:46:34:515] S_MAC-11 D_MAC-49 Poll For Master /Valid 55 FF 01 31 0B 00 00 09 Frame 000272 [2009-08-25 10:46:34:527] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000273 [2009-08-25 10:46:34:687] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0C 0C 0C 00 00 00 F4 19 55 A5 19 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (244), Property ID: present_value Frame 000274 [2009-08-25 10:46:34:846] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 0C 0C 0C 00 00 00 F4 19 55 3E 44 43 7F 00 00 3F FF D9 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (244), Property ID: present_value, Property Value: 255.000 Frame 000275 [2009-08-25 10:46:34:858] S_MAC-50 D_MAC-108 Poll For Master /Valid 55 FF 01 6C 32 00 00 B2 Frame 000276 [2009-08-25 10:46:34:871] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000277 [2009-08-25 10:46:34:883] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000278 [2009-08-25 10:46:34:895] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000279 [2009-08-25 10:46:34:907] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000280 [2009-08-25 10:46:34:067] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0D 0C 0C 02 3F FF FF 19 61 F0 79 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000281 [2009-08-25 10:46:34:227] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 0D 0C 91 01 91 1F D8 B0 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000282 [2009-08-25 10:46:34:239] S_MAC-50 D_MAC-109 Poll For Master /Valid 55 FF 01 6D 32 00 00 3B Frame 000283 [2009-08-25 10:46:34:251] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000284 [2009-08-25 10:46:34:263] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000285 [2009-08-25 10:46:34:275] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000286 [2009-08-25 10:46:35:287] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000287 [2009-08-25 10:46:35:447] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0E 0C 0C 00 00 01 1D 19 55 5B 0B Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (285), Property ID: present_value Frame 000288 [2009-08-25 10:46:35:607] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 0E 0C 0C 00 00 01 1D 19 55 3E 44 43 7F 00 00 3F 69 82 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (285), Property ID: present_value, Property Value: 255.000 Frame 000289 [2009-08-25 10:46:35:619] S_MAC-50 D_MAC-110 Poll For Master /Valid 55 FF 01 6E 32 00 00 A3 Frame 000290 [2009-08-25 10:46:35:631] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000291 [2009-08-25 10:46:35:643] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000292 [2009-08-25 10:46:35:655] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000293 [2009-08-25 10:46:35:667] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000294 [2009-08-25 10:46:35:826] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 0F 0C 0C 02 3F FF FF 19 61 0A E2 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000295 [2009-08-25 10:46:35:983] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 0F 0C 91 01 91 1F 8E B8 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000296 [2009-08-25 10:46:35:996] S_MAC-50 D_MAC-111 Poll For Master /Valid 55 FF 01 6F 32 00 00 2A Frame 000297 [2009-08-25 10:46:35:008] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000298 [2009-08-25 10:46:35:019] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000299 [2009-08-25 10:46:35:032] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000300 [2009-08-25 10:46:35:044] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000301 [2009-08-25 10:46:35:205] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 10 0C 0C 00 00 00 F5 19 55 C2 FC Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (245), Property ID: present_value Frame 000302 [2009-08-25 10:46:36:363] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 10 0C 0C 00 00 00 F5 19 55 3E 44 00 00 00 00 3F A4 18 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (245), Property ID: present_value, Property Value: 0.000 Frame 000303 [2009-08-25 10:46:36:375] S_MAC-50 D_MAC-112 Poll For Master /Valid 55 FF 01 70 32 00 00 5C Frame 000304 [2009-08-25 10:46:36:387] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000305 [2009-08-25 10:46:36:399] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000306 [2009-08-25 10:46:36:412] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000307 [2009-08-25 10:46:36:424] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000308 [2009-08-25 10:46:36:584] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 11 0C 0C 02 3F FF FF 19 61 4B C6 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000309 [2009-08-25 10:46:36:740] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 11 0C 91 01 91 1F 9C C3 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000310 [2009-08-25 10:46:36:752] S_MAC-50 D_MAC-113 Poll For Master /Valid 55 FF 01 71 32 00 00 D5 Frame 000311 [2009-08-25 10:46:36:764] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000312 [2009-08-25 10:46:36:776] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000313 [2009-08-25 10:46:36:788] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000314 [2009-08-25 10:46:36:800] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000315 [2009-08-25 10:46:36:959] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 12 0C 0C 00 00 00 F7 19 55 80 D2 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (247), Property ID: present_value Frame 000316 [2009-08-25 10:46:36:119] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 12 0C 0C 00 00 00 F7 19 55 3E 44 00 00 00 00 3F DB 54 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (247), Property ID: present_value, Property Value: 0.000 Frame 000317 [2009-08-25 10:46:36:132] S_MAC-50 D_MAC-114 Poll For Master /Valid 55 FF 01 72 32 00 00 4D Frame 000318 [2009-08-25 10:46:36:144] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000319 [2009-08-25 10:46:36:157] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000320 [2009-08-25 10:46:36:169] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000321 [2009-08-25 10:46:36:181] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000322 [2009-08-25 10:46:37:342] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 13 0C 0C 02 3F FF FF 19 61 B1 5D Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000323 [2009-08-25 10:46:37:500] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 13 0C 91 01 91 1F CA CB Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000324 [2009-08-25 10:46:37:513] S_MAC-50 D_MAC-115 Poll For Master /Valid 55 FF 01 73 32 00 00 C4 Frame 000325 [2009-08-25 10:46:37:525] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000326 [2009-08-25 10:46:37:537] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000327 [2009-08-25 10:46:37:549] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000328 [2009-08-25 10:46:37:561] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000329 [2009-08-25 10:46:37:719] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 14 0C 0C 00 00 00 FA 19 55 E0 89 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (250), Property ID: present_value Frame 000330 [2009-08-25 10:46:37:879] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 14 0C 0C 00 00 00 FA 19 55 3E 44 3F 80 00 00 3F 59 0E Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (250), Property ID: present_value, Property Value: 1.000 Frame 000331 [2009-08-25 10:46:37:891] S_MAC-50 D_MAC-116 Poll For Master /Valid 55 FF 01 74 32 00 00 7E Frame 000332 [2009-08-25 10:46:37:903] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000333 [2009-08-25 10:46:37:915] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000334 [2009-08-25 10:46:37:927] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000335 [2009-08-25 10:46:37:940] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000336 [2009-08-25 10:46:37:100] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 15 0C 0C 02 3F FF FF 19 61 AE F9 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000337 [2009-08-25 10:46:37:258] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 15 0C 91 01 91 1F 30 D3 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000338 [2009-08-25 10:46:37:271] S_MAC-50 D_MAC-117 Poll For Master /Valid 55 FF 01 75 32 00 00 F7 Frame 000339 [2009-08-25 10:46:38:283] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000340 [2009-08-25 10:46:38:294] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000341 [2009-08-25 10:46:38:307] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000342 [2009-08-25 10:46:38:319] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000343 [2009-08-25 10:46:38:479] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 16 0C 0C 00 00 00 FE 19 55 7B 71 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (254), Property ID: present_value Frame 000344 [2009-08-25 10:46:38:637] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 16 0C 0C 00 00 00 FE 19 55 3E 44 42 08 00 00 3F C5 0B Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (254), Property ID: present_value, Property Value: 34.000 Frame 000345 [2009-08-25 10:46:38:650] S_MAC-50 D_MAC-118 Poll For Master /Valid 55 FF 01 76 32 00 00 6F Frame 000346 [2009-08-25 10:46:38:662] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000347 [2009-08-25 10:46:38:674] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000348 [2009-08-25 10:46:38:686] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000349 [2009-08-25 10:46:38:697] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000350 [2009-08-25 10:46:38:857] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 17 0C 0C 02 3F FF FF 19 61 54 62 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000351 [2009-08-25 10:46:38:015] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 17 0C 91 01 91 1F 66 DB Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000352 [2009-08-25 10:46:38:028] S_MAC-50 D_MAC-119 Poll For Master /Valid 55 FF 01 77 32 00 00 E6 Frame 000353 [2009-08-25 10:46:38:040] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000354 [2009-08-25 10:46:38:053] S_MAC-5 D_MAC-6 Poll For Master /Valid 55 FF 01 06 05 00 00 B1 Frame 000355 [2009-08-25 10:46:38:065] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000356 [2009-08-25 10:46:38:077] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000357 [2009-08-25 10:46:38:089] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000358 [2009-08-25 10:46:38:249] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 18 0C 0C 00 00 00 FD 19 55 CA 45 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (253), Property ID: present_value Frame 000359 [2009-08-25 10:46:39:407] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 18 0C 0C 00 00 00 FD 19 55 3E 44 00 00 00 00 3F 49 21 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (253), Property ID: present_value, Property Value: 0.000 Frame 000360 [2009-08-25 10:46:39:420] S_MAC-50 D_MAC-120 Poll For Master /Valid 55 FF 01 78 32 00 00 18 Frame 000361 [2009-08-25 10:46:39:432] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000362 [2009-08-25 10:46:39:444] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000363 [2009-08-25 10:46:39:457] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000364 [2009-08-25 10:46:39:469] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000365 [2009-08-25 10:46:39:629] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 19 0C 0C 00 00 00 CB 19 55 40 58 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (203), Property ID: present_value Frame 000366 [2009-08-25 10:46:39:787] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 19 0C 0C 00 00 00 CB 19 55 3E 44 42 50 00 00 3F D0 3B Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (203), Property ID: present_value, Property Value: 52.000 Frame 000367 [2009-08-25 10:46:39:800] S_MAC-50 D_MAC-121 Poll For Master /Valid 55 FF 01 79 32 00 00 91 Frame 000368 [2009-08-25 10:46:39:813] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000369 [2009-08-25 10:46:39:826] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000370 [2009-08-25 10:46:39:839] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000371 [2009-08-25 10:46:39:851] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000372 [2009-08-25 10:46:39:010] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1A 0C 0C 00 00 00 CA 19 55 9B D4 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (202), Property ID: present_value Frame 000373 [2009-08-25 10:46:39:172] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 1A 0C 0C 00 00 00 CA 19 55 3E 44 42 40 00 00 3F 77 4E Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (202), Property ID: present_value, Property Value: 48.000 Frame 000374 [2009-08-25 10:46:39:185] S_MAC-50 D_MAC-122 Poll For Master /Valid 55 FF 01 7A 32 00 00 09 Frame 000375 [2009-08-25 10:46:39:198] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000376 [2009-08-25 10:46:39:210] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000377 [2009-08-25 10:46:39:223] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000378 [2009-08-25 10:46:39:236] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000379 [2009-08-25 10:46:40:396] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1B 0C 0C 00 00 00 C9 19 55 02 76 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (201), Property ID: present_value Frame 000380 [2009-08-25 10:46:40:556] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 1B 0C 0C 00 00 00 C9 19 55 3E 44 42 38 00 00 3F 93 0B Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (201), Property ID: present_value, Property Value: 46.000 Frame 000381 [2009-08-25 10:46:40:570] S_MAC-50 D_MAC-123 Poll For Master /Valid 55 FF 01 7B 32 00 00 80 Frame 000382 [2009-08-25 10:46:40:583] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000383 [2009-08-25 10:46:40:595] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000384 [2009-08-25 10:46:40:608] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000385 [2009-08-25 10:46:40:620] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000386 [2009-08-25 10:46:40:780] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1C 0C 0C 00 00 00 C8 19 55 3C C5 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (200), Property ID: present_value Frame 000387 [2009-08-25 10:46:40:939] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 1C 0C 0C 00 00 00 C8 19 55 3E 44 42 54 00 00 3F 27 9B Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (200), Property ID: present_value, Property Value: 53.000 Frame 000388 [2009-08-25 10:46:40:952] S_MAC-50 D_MAC-124 Poll For Master /Valid 55 FF 01 7C 32 00 00 3A Frame 000389 [2009-08-25 10:46:40:965] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000390 [2009-08-25 10:46:40:978] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000391 [2009-08-25 10:46:40:990] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000392 [2009-08-25 10:46:40:003] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000393 [2009-08-25 10:46:40:164] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1D 0C 0C 02 3F FF FF 19 61 64 86 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000394 [2009-08-25 10:46:41:324] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 1D 0C 91 01 91 1F 68 F2 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000395 [2009-08-25 10:46:41:337] S_MAC-50 D_MAC-125 Poll For Master /Valid 55 FF 01 7D 32 00 00 B3 Frame 000396 [2009-08-25 10:46:41:350] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000397 [2009-08-25 10:46:41:363] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000398 [2009-08-25 10:46:41:375] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000399 [2009-08-25 10:46:41:388] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000400 [2009-08-25 10:46:41:549] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1E 0C 0C 00 00 00 E8 19 55 FD 5D Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (232), Property ID: present_value Frame 000401 [2009-08-25 10:46:41:719] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 1E 0C 0C 00 00 00 E8 19 55 3E 44 3F 80 00 00 3F B0 C0 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (232), Property ID: present_value, Property Value: 1.000 Frame 000402 [2009-08-25 10:46:41:734] S_MAC-50 D_MAC-0 Poll For Master /Valid 55 FF 01 00 32 00 00 E1 Frame 000403 [2009-08-25 10:46:41:746] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000404 [2009-08-25 10:46:41:759] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000405 [2009-08-25 10:46:41:772] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000406 [2009-08-25 10:46:41:785] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000407 [2009-08-25 10:46:41:945] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 1F 0C 0C 00 00 00 F2 19 55 EF E6 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (242), Property ID: present_value Frame 000408 [2009-08-25 10:46:41:105] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 1F 0C 0C 00 00 00 F2 19 55 3E 44 42 B3 2B 02 3F 00 B4 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (242), Property ID: present_value, Property Value: 89.584 Frame 000409 [2009-08-25 10:46:41:118] S_MAC-50 D_MAC-1 Poll For Master /Valid 55 FF 01 01 32 00 00 68 Frame 000410 [2009-08-25 10:46:41:131] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000411 [2009-08-25 10:46:41:144] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000412 [2009-08-25 10:46:41:157] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000413 [2009-08-25 10:46:41:169] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000414 [2009-08-25 10:46:41:183] S_MAC-50 D_MAC-2 Poll For Master /Valid 55 FF 01 02 32 00 00 F0 Frame 000415 [2009-08-25 10:46:41:196] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000416 [2009-08-25 10:46:41:208] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000417 [2009-08-25 10:46:41:221] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000418 [2009-08-25 10:46:41:234] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000419 [2009-08-25 10:46:42:394] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 20 0C 0C 02 3F FF FF 19 61 1B 83 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000420 [2009-08-25 10:46:42:552] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 20 0C 91 01 91 1F 67 00 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000421 [2009-08-25 10:46:42:566] S_MAC-50 D_MAC-3 Poll For Master /Valid 55 FF 01 03 32 00 00 79 Frame 000422 [2009-08-25 10:46:42:578] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000423 [2009-08-25 10:46:42:591] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000424 [2009-08-25 10:46:42:603] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000425 [2009-08-25 10:46:42:616] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000426 [2009-08-25 10:46:42:777] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 21 0C 0C 00 00 01 15 19 55 88 AC Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (277), Property ID: present_value Frame 000427 [2009-08-25 10:46:42:937] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 21 0C 0C 00 00 01 15 19 55 3E 44 42 32 D3 31 3F AB 1B Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (277), Property ID: present_value, Property Value: 44.706 Frame 000428 [2009-08-25 10:46:42:950] S_MAC-50 D_MAC-4 Poll For Master /Valid 55 FF 01 04 32 00 00 C3 Frame 000429 [2009-08-25 10:46:42:963] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000430 [2009-08-25 10:46:42:976] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000431 [2009-08-25 10:46:42:989] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000432 [2009-08-25 10:46:42:002] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000433 [2009-08-25 10:46:42:164] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 22 0C 0C 02 3F FF FF 19 61 E1 18 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000434 [2009-08-25 10:46:43:328] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 22 0C 91 01 91 1F 31 08 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000435 [2009-08-25 10:46:43:341] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000436 [2009-08-25 10:46:43:354] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000437 [2009-08-25 10:46:43:367] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000438 [2009-08-25 10:46:43:379] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000439 [2009-08-25 10:46:43:542] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 23 0C 0C 00 00 00 F0 19 55 D5 1B Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (240), Property ID: present_value Frame 000440 [2009-08-25 10:46:43:701] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 23 0C 0C 00 00 00 F0 19 55 3E 44 42 59 AD AC 3F 9F F9 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (240), Property ID: present_value, Property Value: 54.420 Frame 000441 [2009-08-25 10:46:43:714] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000442 [2009-08-25 10:46:43:727] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000443 [2009-08-25 10:46:43:741] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000444 [2009-08-25 10:46:43:753] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000445 [2009-08-25 10:46:43:914] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 24 0C 0C 02 3F FF FF 19 61 FE BC Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000446 [2009-08-25 10:46:43:073] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 24 0C 91 01 91 1F CB 10 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000447 [2009-08-25 10:46:43:087] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000448 [2009-08-25 10:46:43:100] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000449 [2009-08-25 10:46:43:112] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000450 [2009-08-25 10:46:43:125] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000451 [2009-08-25 10:46:44:292] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 25 0C 0C 00 00 01 19 19 55 CE 36 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (281), Property ID: present_value Frame 000452 [2009-08-25 10:46:44:453] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 25 0C 0C 00 00 01 19 19 55 3E 44 42 A0 75 5A 3F 36 65 Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (281), Property ID: present_value, Property Value: 80.229 Frame 000453 [2009-08-25 10:46:44:466] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000454 [2009-08-25 10:46:44:480] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000455 [2009-08-25 10:46:44:493] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000456 [2009-08-25 10:46:44:506] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000457 [2009-08-25 10:46:44:669] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 26 0C 0C 02 3F FF FF 19 61 04 27 Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported Frame 000458 [2009-08-25 10:46:44:828] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 0E 64 01 20 57 4C 01 32 FF 50 26 0C 91 01 91 1F 9D 18 Pdu: error_pdu, Error Class: 1, Error Code: 31 Frame 000459 [2009-08-25 10:46:44:841] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000460 [2009-08-25 10:46:44:854] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000461 [2009-08-25 10:46:44:867] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000462 [2009-08-25 10:46:44:880] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000463 [2009-08-25 10:46:44:042] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 27 0C 0C 00 00 00 F3 19 55 54 CB Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Analog_input (243), Property ID: present_value Frame 000464 [2009-08-25 10:46:44:204] S_MAC-5 D_MAC-50 Data Not Expecting Reply/Valid 55 FF 06 32 05 00 18 97 01 20 57 4C 01 32 FF 30 27 0C 0C 00 00 00 F3 19 55 3E 44 42 9F 80 00 3F CC 2F Pdu: complex_ack_pdu, Type: read_property_ack Object ID: Analog_input (243), Property ID: present_value, Property Value: 79.750 Frame 000465 [2009-08-25 10:46:44:232] S_MAC-50 D_MAC-5 Token /Valid 55 FF 00 05 32 00 00 CC Frame 000466 [2009-08-25 10:46:44:245] S_MAC-5 D_MAC-7 Token /Valid 55 FF 00 07 05 00 00 BE Frame 000467 [2009-08-25 10:46:44:258] S_MAC-7 D_MAC-11 Token /Valid 55 FF 00 0B 07 00 00 EB Frame 000468 [2009-08-25 10:46:44:271] S_MAC-11 D_MAC-50 Token /Valid 55 FF 00 32 0B 00 00 17 Frame 000469 [2009-08-25 10:46:45:432] S_MAC-50 D_MAC-5 Data Expecting Reply /Valid 55 FF 05 05 32 00 11 5B 01 0C 57 4C 01 32 00 03 28 0C 0C 02 3F FF FF 19 61 D1 FC Pdu: confirmed_request_pdu, Type: read_property_request Object ID: Device (4194303), Property ID: protocol_services_supported