Device type: Active Master
Note: "A Device that responds and passes the token"
Total Messages Sent: 63
Tolal Messages Received: 60
-------------------------------------------------------------------------------
Table of Sent/Received MSTP Frames:
-------------------------------------------------------------------------------
00 Token Sent: 60 - 95
00 Token Received: 60 - 100
01 Poll For Master Sent: 3 - 4
01 Poll For Master Received: 0 - 0
02 Reply To Poll For Master Sent: 0 - 0
02 Reply To Poll For Master Received: 0 - 0
03 Test_Request Sent: 0 - 0
03 Test_Request Received: 0 - 0
04 Test_Response Sent: 0 - 0
04 Test_Response Received: 0 - 0
05 Data Expecting Reply Sent: 0 - 0
05 Data Expecting Reply Received: 0 - 0
06 Data Not Expecting Reply Sent: 0 - 0
06 Data Not Expecting Reply Received: 0 - 0
07 Reply Postponed Sent: 0 - 0
07 Reply Postponed Received: 0 - 0
-------------------------------------------------------------------------------
Table of Token time:
-------------------------------------------------------------------------------
longest shortest
Time between receiving the token : 3599399ms 64ms
Time holding the token : 25ms 11ms
Start at [2009-08-25 10:46:44:258] Received 60 Tokens. The Average receive time is : 840370ms. Holding time : 12ms
-------------------------------------------------------------------------------
Pdu Types Count:
-------------------------------------------------------------------------------
Recv : complex_ack_pdu : 19
Recv : error_pdu : 1
Recv : simple_ack_pdu : 4
Sent : complex_ack_pdu : 19
Sent : error_pdu : 1
Sent : simple_ack_pdu : 4
-------------------------------------------------------------------------------
Pdu Types by Object ID:
-------------------------------------------------------------------------------
Analog output (101)
Recv
simple_ack_pdu : 1
Sent
simple_ack_pdu : 1
Analog output (102)
Recv
simple_ack_pdu : 1
Sent
simple_ack_pdu : 1
Analog output (104)
Recv
simple_ack_pdu : 1
Sent
simple_ack_pdu : 1
Analog output (115)
Recv
simple_ack_pdu : 1
Sent
simple_ack_pdu : 1
Analog_input (200)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (201)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (202)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (203)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (232)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (240)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (241)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (242)
Recv
complex_ack_pdu : 3
Sent
complex_ack_pdu : 3
Analog_input (243)
Recv
complex_ack_pdu : 3
Sent
complex_ack_pdu : 3
Analog_input (244)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (245)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (247)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (250)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (253)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (254)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 2
Analog_input (277)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Analog_input (281)
Recv
complex_ack_pdu : 2
Sent
complex_ack_pdu : 3
Analog_input (285)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Binary input (100)
Recv
complex_ack_pdu : 1
Sent
complex_ack_pdu : 1
Device (4194303)
Recv
error_pdu : 25
Sent
error_pdu : 27