TAC I/NET Converters

Up one level

 

 

The TAC I/Net 2000 protocol driver is available as a client and a server. The client can poll MR devices on a MR LAN. The server can emulate MR devices on a MR LAN. The client and server drivers both support quick polling. Quick polling refers to the ability to only report changed data whereas normal polling reports all data irrespective of changes. The drivers support the basic TAC I/Net data points. Data may be collected and stored in any combinations of input and output points making it easier to move data around. Only the specified TAC I/Net type data will be stored.

 

Convert

 

We have module solutions which allow integration directly into TAC I/NET products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

 

    FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
    FS25 Series 2x RS232/485 1x Ethernet
    FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
    Hot Standby Support
    FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
    Hot Standby Support
    SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

    Lonworks and Fieldbus are options not proviced on base models.

 

Find your protocol

 

We have a huge list of protocols.

 

Block Diagram

 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Chipkin Automation Systems

 

1. Experience working with TAC  data conversion. We have sold and installed many systems connecting TAC I/net  to foreign building management systems and devices.

2. We are system integration specialists. We have worked with most of the Building Automation Systems before.

3. We provide a free CAS BACnet explorer when you integrate to a system using BACnet. This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and give you confidence should the dreaded ‘integration finger pointing’ occur.

 

Data Sheets and Manuals

 

- Data Sheet - FieldServer Driver - Serial - FS-8700-71 - TAC I/Net 2000

- Manual - FieldServer Driver - Serial - FS-8700-71 - TAC I/Net 2000

More Data Sheets...

 

Need Help

 

TAC I/NET Web Site: www.tac.com

Need more info ? Call or email us.