Connecting BACnet to SIA

You have two devices in two different buildings on two completely different networks, one that uses the BACnet MSTP protocol to communicate, while the other one talks SIA Security Industry protocol and they need to talk to each other. What do you do?

A FieldServer is a protocol converter or gateway that can communicate in many different protocols and physical layers including BACnet MSTP protocol and the SIA Security Industry protocol. The Fieldserver acts as a middle man between the two devices. It reads data from one device, stores it internally and makes it available to the 2nd device using another protocol. This is how the FieldServer converts BACnet MSTP data to SIA Security Industry data.

It's a simple solution to a common problem that we can help you with.

Contact us:

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882

BACnet MSTP

BACnet MSTP is part of the ASHRAE’s BACnet family of protocols that operates on the MSTP RS485 network. With the help of FieldServer we can set and retrieve BACnet data from your device and make it available to many different devices no matter what protocol they use. The FieldServer can convert BACnet MSTP to an impressive set of other building automation protocols by acting as a middle man or protocol converter between two different protocols. Talks BACnet MSTP on one side and anything else on the other. More information, Driver Data Sheet

SIA Security Industry

The driver provides an interface to alarm panels that support the Security Industry Association (SIA) codes, The panel sends a message each time there is an event. In addition the panel sends a empty message periodically. When an acknowledgement is sent in response to the empty message (or in response to other messages) the panel knows that the connection is good and that the messages are being monitored.


When an event message arrives, the driver breaks out the data, determining the event type. The event type tells the driver whether the event applies to a zone, printer, line, door, area etc. Now the driver can determine, the zone, printer, door (… etc) number. This gives the driver enough information on where to store the event data. If a new event occurs for that zone (for example) then the previous event data is overwritten.

More information, Driver Data Sheet

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1020 1x RS485 1xRS232 1x Ethernet
QuickServer 1021 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600
Lonworks and Fieldbus are options not provided on base models.  

Connection Diagram

BACnet MSTP

FieldServer

SIA Security Industry

Purchase Now

You can purchase some of these items now at ModbusBACnet.com. We keep stock of most gateways and CAS can often ship for next day delivery. Often we need to do due diligence with you, check the number of devices, trunks, points , network routing and many other factors and thus we like a chance to chat to you, learn your project requirements and work with you to provide the most effective solution. Contact us.

Configuration and Support

With CAS you are purchasing a solution - not a commodity. If you ask CAS to do the gateway configuration for you then you are purchasing a solution from us and we will work with you to pre-configure the device, make changes as you require them, keep a backup of your files and provide support for you and your customer when installation is done.

CAS are famous for a high level of effective and responsive support. We work with you using voice, email and remote desktop applications.

Contact us

We have the solution that you are looking for, please contact us today.

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882
Your name:
Your email address:
Your enquiry:

Do you want a response? Please include your contact info and email address