Connecting Profibus to Modbus

You have two devices in two different buildings on two completely different networks, one that uses the Profibus protocol to communicate, while the other one talks Modbus protocol and they need to talk to each other. What do you do?

A FieldServer is a protocol converter or gateway that can communicate in many different protocols and physical layers including Profibus protocol and the Modbus protocol. The Fieldserver acts as a middle man between the two devices. It reads data from one device, stores it internally and makes it available to the 2nd device using another protocol. This is how the FieldServer converts Profibus data to Modbus data.

It's a simple solution to a common problem that we can help you with.

Contact us:

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882

Profibus

The FieldServer Profibus protocol translator/gateway provides a wealth of features to enable data transfer between Profibus DP networks and different devices and networks utilizing serial, Ethernet or LonWorks protocols. The extensive library of FieldServer drivers provides easy Profibus DP interoperability with devices and networks used in building automation, HVAC, fire and process control industries.


Support is provided for Master and Server applications.


The FieldServer Profibus DP Master driver for the FS-B3520 can be used to transfer I/O data with up to 125 Profibus DP Slave devices. The FieldServer is programmed with an embedded database using the required third part configuration tool. The embedded database contains information on the number of slaves and I/O modules to be transferred with each slave. The tool requires the input of GSD/E files for each slave to be connected.


More information, Driver Data Sheet

Modbus

There are a number of flavors of Modbus. Our gateways supports them all.

  • Modbus RTU
  • Modbus Ascii (802.3)
  • Modbus JBUS
  • Modbus TCP/IP
  • Modbus MB+
  • Various others variations like Enron, Daniels ....

  • You can read more about the flavors at this page: Flavors of Modbus
    Our gateways can act as clients / servers or both at the same time.

    We provide free Modbus Test Software

    Need multiple masters to talk to one slave ? Our gateways can do this. More information

    Modbus to BACnet Gateways


  • Modbus RTU to BACnet IP
  • Modbus RTU to BACnet MSTP
  • Modbus RTU to BACnet Arcnet
  • Modbus RTU to BACnet IP

  • Modbus TCP to BACnet IP
  • Modbus TCP to BACnet MSTP
  • Modbus TCP to BACnet Arcnet
  • Modbus TCP to BACnet IP

  • Modbus Plus (MB) to BACnet Ethernet
  • Modbus Plus (MB) to BACnet IP
  • Modbus Plus (MB) to BACnet MSTP
  • Modbus Plus (MB) to BACnet Arcnet

  • Modbus ASCII to BACnet Ethernet
  • Modbus ASCII to BACnet IP
  • Modbus ASCII to BACnet MSTP
  • Modbus ASCII to BACnet Arcnet

  • Modbus JBUS to BACnet Ethernet
  • Modbus JBUS to BACnet IP
  • Modbus JBUS to BACnet MSTP
  • Modbus JBUS to BACnet ARCnet
  • Range of Conversion Solutions

    Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
    QuickServer 1010 2x RS485 1x Ethernet
    QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
    QuickServer 1020 1x RS485 1xRS232 1x Ethernet
    QuickServer 1021 1x RS485 1xRS232 1x Ethernet 1x Lonworks
    QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
    FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
    FS25 Series 2x RS232/485 1x Ethernet
    FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
    FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
    SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600
    Lonworks and Fieldbus are options not provided on base models.  

    Connection Diagram

    Purchase Now

    You can purchase some of these items now at ModbusBACnet.com. We keep stock of most gateways and CAS can often ship for next day delivery. Often we need to do due diligence with you, check the number of devices, trunks, points , network routing and many other factors and thus we like a chance to chat to you, learn your project requirements and work with you to provide the most effective solution. Contact us.

    Configuration and Support

    With CAS you are purchasing a solution - not a commodity. If you ask CAS to do the gateway configuration for you then you are purchasing a solution from us and we will work with you to pre-configure the device, make changes as you require them, keep a backup of your files and provide support for you and your customer when installation is done.

    CAS are famous for a high level of effective and responsive support. We work with you using voice, email and remote desktop applications.

    Contact us

    We have the solution that you are looking for, please contact us today.

    Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882
    Your name:
    Your email address:
    Your enquiry:

    Do you want a response? Please include your contact info and email address