Connecting Cummins to TAC

You have two devices in two different buildings on two completely different networks, one that uses the Cummins protocol to communicate, while the other one talks TAC I-Net protocol and they need to talk to each other. What do you do?

A FieldServer is a protocol converter or gateway that can communicate in many different protocols and physical layers including Cummins protocol and the TAC I-Net protocol. The Fieldserver acts as a middle man between the two devices. It reads data from one device, stores it internally and makes it available to the 2nd device using another protocol. This is how the FieldServer converts Cummins data to TAC I-Net data.

It's a simple solution to a common problem that we can help you with.

Contact us:

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882

Cummins

Cummins generator and Automatic Transfer Switches (ATS) controls support Lonworks on a FTT10 network. We have worked closely with Cummins Western Canada to develop tested interfaces to BACnet and other protocols.


Our solutions can be configured so that you do not need to 'Commission' and 'Bind'. These two processes require Lonworks software tools and expertise. If required we can avoid this by using an explicit lonworks configuration which uses Network Management functions for data transfer. This type of solution works as effectively but makes installation very simple.


We have provided solutions for Power Command controllers ATS, PCC2101, PCC2100, PCC3200, PCC3201, PCC1301, PCC1302


Our solutions offer more connectivity than the Modlon which supports Modbus with limited options.

More information

TAC I-Net

Profibus, utility companies, hospitals, universities, national laboratories-they all require seamless and 100-percent effective security systems they can depend on day in and day out. TAC and I/NET Seven provide powerful and reliable security solutions for some of the world’s most demanding applications, with features that make your systems easy to install, operate, integrate, expand and maintain-throughout the life of your facilities.


I/NET Seven is a powerful and reliable security solution with features that make your systems easy to install, operate, integrate, expand and maintain – throughout the life of your facilities. No other security product gives you the power of I/NET Seven backed by the experience and expertise of an industry leader. You can rely on TAC and I/NET Seven for all your security needs.


The TAC-I/Net driver allows the FieldServer to transfer data to and from Server and Client devices on a MR LAN over RS-485 using TAC-I/Net driver protocol. The protocol works over a multidrop RS-485 line and allows only one Client and up to 32 Servers on a network channel. Servers are assigned station addresses that range from 0 to 31. The Client does not have a station address. If more than 320 points are needed on the I/net network an alternative is for the customer to purchase the 7797-15 Modbus RTU interface card. This interface card will allow 2000 points to be passed to the I/net Sublan. This will change the application from I/net to Modbus, but it will work.


More information, Driver Data Sheet

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1020 1x RS485 1xRS232 1x Ethernet
QuickServer 1021 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600
Lonworks and Fieldbus are options not provided on base models.  

Connection Diagram

Cummins

FieldServer

TAC I-Net

Purchase Now

You can purchase some of these items now at ModbusBACnet.com. We keep stock of most gateways and CAS can often ship for next day delivery. Often we need to do due diligence with you, check the number of devices, trunks, points , network routing and many other factors and thus we like a chance to chat to you, learn your project requirements and work with you to provide the most effective solution. Contact us.

Configuration and Support

With CAS you are purchasing a solution - not a commodity. If you ask CAS to do the gateway configuration for you then you are purchasing a solution from us and we will work with you to pre-configure the device, make changes as you require them, keep a backup of your files and provide support for you and your customer when installation is done.

CAS are famous for a high level of effective and responsive support. We work with you using voice, email and remote desktop applications.

Contact us

We have the solution that you are looking for, please contact us today.

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882
Your name:
Your email address:
Your enquiry:

Do you want a response? Please include your contact info and email address