Connecting BACnet to Optomux

You have two devices in two different buildings on two completely different networks, one that uses the BACnet Ethernet protocol to communicate, while the other one talks Optomux Opto22 protocol and they need to talk to each other. What do you do?

A FieldServer is a protocol converter or gateway that can communicate in many different protocols and physical layers including BACnet Ethernet protocol and the Optomux Opto22 protocol. The Fieldserver acts as a middle man between the two devices. It reads data from one device, stores it internally and makes it available to the 2nd device using another protocol. This is how the FieldServer converts BACnet Ethernet data to Optomux Opto22 data.

It's a simple solution to a common problem that we can help you with.

Contact us:

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882

BACnet Ethernet

BACnet Ethernet is part of the ASHRAE’s BACnet family of protocols that operates on the Ethernet network. BACnet is mainly used for HVAC systems but recently has started showing up in all types of industrial automation, building automation networks and intelligent buildings.
With the help of a Fieldserver protocol converter we can set and retrieve BACnet Ethernet points, properties, and settings from your device and make them available to other networks and devices. The Fieldserver BACnet protocol driver can convert BACnet Ethernet to an impressive set of other building automation protocols by acting as a protocol converter or gateway. More information, Driver Data Sheet

Optomux Opto22

The Optomux Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS-485 using the Optomux Driver protocol. The Optomux driver is a client only driver and can poll an Optomux protocol compliant device but not emulate one.


The Optomux protocol provides a large command set. Many of the commands are used for OPTO22 device configuration. This driver supports the full command set and thus the driver may be used to configure as well as to poll OPTO22 devices.




Operating Methods


The Optomux driver provides three methods of operation. Users may use any combination of methods.


Static Operation : If the hardware configuration is fixed and known then this is a suitable method. The devices to be polled/commanded are configured using the FieldServer CSV file.


Dynamic Operation : If the hardware configuration may change or if hardware settings may change dynamically or (more realistically) if you wish to change some aspect of the hardware configuration such as a delay time or reset a latch without changing the CSV file and resetting the FieldServer then this operating method is suitable. The commands set can be configured by changing the values in the FieldServer’s data arrays. This operating mode may be considered a data driven one.


Triggered Operation : This operating mode allows commands to be triggered by changing the value in the FieldServer’s data arrays. This operating mode is useful if requiring an action triggered by a remote device.


More information, Driver Data Sheet

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1020 1x RS485 1xRS232 1x Ethernet
QuickServer 1021 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600
Lonworks and Fieldbus are options not provided on base models.  

Connection Diagram

BACnet Ethernet

FieldServer

Optomux Opto22

Purchase Now

You can purchase some of these items now at ModbusBACnet.com. We keep stock of most gateways and CAS can often ship for next day delivery. Often we need to do due diligence with you, check the number of devices, trunks, points , network routing and many other factors and thus we like a chance to chat to you, learn your project requirements and work with you to provide the most effective solution. Contact us.

Configuration and Support

With CAS you are purchasing a solution - not a commodity. If you ask CAS to do the gateway configuration for you then you are purchasing a solution from us and we will work with you to pre-configure the device, make changes as you require them, keep a backup of your files and provide support for you and your customer when installation is done.

CAS are famous for a high level of effective and responsive support. We work with you using voice, email and remote desktop applications.

Contact us

We have the solution that you are looking for, please contact us today.

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882
Your name:
Your email address:
Your enquiry:

Do you want a response? Please include your contact info and email address