Connecting BACnet to Omron

You have two devices in two different buildings on two completely different networks, one that uses the BACnet Ethernet protocol to communicate, while the other one talks Omron FINS protocol and they need to talk to each other. What do you do?

A FieldServer is a protocol converter or gateway that can communicate in many different protocols and physical layers including BACnet Ethernet protocol and the Omron FINS protocol. The Fieldserver acts as a middle man between the two devices. It reads data from one device, stores it internally and makes it available to the 2nd device using another protocol. This is how the FieldServer converts BACnet Ethernet data to Omron FINS data.

It's a simple solution to a common problem that we can help you with.

Contact us:

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882

BACnet Ethernet

BACnet Ethernet is part of the ASHRAE’s BACnet family of protocols that operates on the Ethernet network. BACnet is mainly used for HVAC systems but recently has started showing up in all types of industrial automation, building automation networks and intelligent buildings.
With the help of a Fieldserver protocol converter we can set and retrieve BACnet Ethernet points, properties, and settings from your device and make them available to other networks and devices. The Fieldserver BACnet protocol driver can convert BACnet Ethernet to an impressive set of other building automation protocols by acting as a protocol converter or gateway. More information, Driver Data Sheet

Omron FINS

The Omron FINS driver can be used by a PLC program to transfer data and perform other services with a remote PLC connected on an Ethernet Network. The Omron FINS protocol can be used by remote devices such a FieldServer to transfer data and perform other services. The protocol uses the Ethernet protocol called UDP to carry the Omron FINS messages back and forth. The UDP protocol is not connection based and reliability is achieved by using confirmation messages. This Ethernet Driver can be used to transfer data to and from the Nodes supporting Omron FINS communications. The Driver can be configured as a Client or a Server. More information, Driver Data Sheet

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1020 1x RS485 1xRS232 1x Ethernet
QuickServer 1021 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600
Lonworks and Fieldbus are options not provided on base models.  

Connection Diagram

BACnet Ethernet

FieldServer

Omron FINS

Purchase Now

You can purchase some of these items now at ModbusBACnet.com. We keep stock of most gateways and CAS can often ship for next day delivery. Often we need to do due diligence with you, check the number of devices, trunks, points , network routing and many other factors and thus we like a chance to chat to you, learn your project requirements and work with you to provide the most effective solution. Contact us.

Configuration and Support

With CAS you are purchasing a solution - not a commodity. If you ask CAS to do the gateway configuration for you then you are purchasing a solution from us and we will work with you to pre-configure the device, make changes as you require them, keep a backup of your files and provide support for you and your customer when installation is done.

CAS are famous for a high level of effective and responsive support. We work with you using voice, email and remote desktop applications.

Contact us

We have the solution that you are looking for, please contact us today.

Call us: 1-866-383-1657 (Toll Free) or (778) 370-3882
Your name:
Your email address:
Your enquiry:

Do you want a response? Please include your contact info and email address