SNMP Data Conversion

Up one level

There are two solution platforms for SNMP

  • FieldServer - FieldServer can read data using over 110 protocols from device like Fire Panels, PLC’s Gensets, HVAC etc. Almost all of this data can be served as SNMP data – you poll for it and/or it can be served as traps. In addition, FieldServers can monitor SNMP enabled devices such as UPS’s and serve that data using other protocols so the data can be integrated into Building and Industrial Systems. S4 Open
  • The S4 Open platform connects SNMP enabled devices to an OPC server so HMI’s and control systems can monitor and command the SNMP enabled devices. A high degree of automation is provided based on automatic discovery of SNMP devices and walks through their MIB trees.

 

Convert

 

We have module solutions which allow integration directly into SNMP as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

 

    FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
    FS25 Series
    2x RS232/485 1x Ethernet
    FS30 Series
    2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
    Hot Standby Support
    FS40 Series
    10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
    Hot Standby Support
    SlotServer
    1x RS232/485
    1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

    Lonworks and Fieldbus are options not proviced on base models.

 

Find your protocol

 

We have a huge list of protocols.

 

Block Diagram

 

The block diagram below illustrates the FieldServer Platform solution

 

 

The block diagram below illustrates the S4 Open solution platform

  • Translates OPC Read Requests to SNMP GET Commands
  • Translates OPC Write Requests to SNMP SET Commands
  • Maps SNMP Traps to OPC Alarms and Events
  • Supports SNMP Autodiscovery
  • Automatically selects the correct Device Profile and assigns it to SNMP devices
  • Integrates SNMP Manageable devices into Automation Systems
  • Supports NON-SNMP devices via ICMP

 

 

Data Sheets and Manuals

 

- Data Sheet - FieldServer Driver - Ethernet - FS-8704-09 - SNMP

- Manual - FieldServer Driver - Ethernet - FS-8704-09 - SNMP

- S4 Group - The Obermeier Software SNMP OPC Server v3.0 Product Sheet

More Data Sheets...

 

Need Help

 

SNMP Web Site: www.net-snmp.org

Need more info ? Call or email us.