XML Gateways

XML Gateways and Converters Introduction

Any data that can be read and or written by a FieldServer can be made available as XML data. There are several schema’s that can be used.
As you are probably aware, XML provides a structure to define a data transfer method but does not define the method itself. To exchange data the structure and content of message must be recognizable by both parties in the exchange. Having a common structure (XML) is not enough itself.  There are several XML drivers for the FieldServer gateways. One set is provided for remote systems to query/set data in FieldServer data arrays.  This XML schema is available as a UDP, TCP or even serial driver. Another driver available for XML has a more flexible schema that allows the FieldServer to read/write data from XML servers. Finally we have a couple of XML drivers that were developed for specific customers to meet specific schema requirements. An example of one of these drivers is one specifically aimed as transferring schedule data from and XML server to.

 

Convert

We have module solutions which allow integration directly into XML as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Data Sheets and Manuals

 – Data Sheet – FieldServer Driver – Ethernet – FS-8704-15 – XML

Data Sheet – FieldServer Driver – Serial – FS-8704-15 – XML White Paper

Manual – FieldServer Driver – Serial – FS-8704-15 – XML White Paper

Data Sheet – FieldServer Driver – Serial – FS-8704-01 – SMC TCP/IP

Manual – FieldServer Driver – Serial – FS-8704-01 – SMC TCP/IP

Data Sheet – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Manual – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Manual – FieldServer Driver – FS-8704-03 – Convia XML

Data Sheet – FieldServer Driver – FS-8704-03 – Convia XML

Data Sheet – FieldServer Driver – Serial – FS-8705-14 – Harshaw Trane – Driver for XML HVAC Building Automation Schedules

More Data Sheets

 

Need Help

XML Web Site: www.xml.com

Need more info ? Call or email us.