There are two solution platforms for SNMP

  • FieldServer – FieldServer can read data using over 110 protocols from device like Fire Panels, PLC’s Gensets, HVAC etc. Almost all of this data can be served as SNMP data – you poll for it and/or it can be served as traps. In addition, FieldServers can monitor SNMP enabled devices such as UPS’s and serve that data using other protocols so the data can be integrated into Building and Industrial Systems.

FieldServer have 2x SNMP Drivers. They are both v1 drivers and while similar they have important differences in the way TRAPS carry their payload and some other important differences.

SNMP — FS-8704-09 (aka FieldServer legacy SNMP Driver)

SNMP — FS-8704-26 (aka FieldServer Standard SNMP Driver)

 

  • S4 Open – The S4 Open platform connects SNMP enabled devices to an OPC server so HMI’s and control systems can monitor and command the SNMP enabled devices. A high degree of automation is provided based on automatic discovery of SNMP devices and walks through their MIB trees.

 

Convert

We have module solutions which allow integration directly into SNMP as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Block Diagram

The block diagram below illustrates the FieldServer Platform solution

S4 Solutions for SNMP to OPC

The block diagram below illustrates the S4 Open solution platform

  • Translates OPC Read Requests to SNMP GET Commands
  • Translates OPC Write Requests to SNMP SET Commands
  • Maps SNMP Traps to OPC Alarms and Events
  • Supports SNMP Autodiscovery
  • Automatically selects the correct Device Profile and assigns it to SNMP devices
  • Integrates SNMP Manageable devices into Automation Systems
  • Supports NON-SNMP devices via ICMP

 


Data Sheets and Manuals

 

Data Sheet – FieldServer Driver – Ethernet – FS-8704-09 – SNMP

Manual – FieldServer Driver – Ethernet – FS-8704-09 – SNMP

S4 Group – The Obermeier Software SNMP OPC Server v3.0 Product Sheet

More Data Sheets

 