Veeder Gateways

 

List of Gateways

Veeder

 

 

 

This FieldServer driver was developed for FST by Chipkin Automation Systems. Get expert support faster when you use Chipkin Automation Systems.

Originally developed for the 350 series the driver has been tested on both 300 and 450 systems. We can convert any data to most other protocols and the driver supports system , in tank, inventory and system reports. Control functions such as reset are also supported.

There are 3 solutions:

CAS-2700-02-Veeder Root TLC 300, 350/450 Gateway – Modbus and BACnet and HTML (Web)

 

VeederSolutionImage1

The Veeder Serial Driver allows the Gateway to poll Veeder TLS Panel’s for status, real time and configuration data. Thus the driver can be used to read Tank Inventory, System Status, Tank Alarms, Sensor Alarms and more …read more

CAS-2700-03-Veeder TCP – TLS 300, 350, 450 – Modbus (RTU and TCP) and BACnet and HTML Gateway

 

 

CAS-2700-12-CAS-2700-12-Veeder TLS 300, 350, 450 – Modbus Gateway

 

 

2700-12

Convert

We have module solutions which allow integration directly into Veeder-Root products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

 

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Chipkin Automation and Veeder-Root

The Veeder Root driver was developed by Chipkin Automation Systems for FST. We continue to provide 2nd tier support to FST. We know this protocol to source code level – get expert support and configuration from day 1.

 

Data Sheets and Manuals

Manual – FieldServer Driver – Serial – FS-8700-74 – Veeder-Root Serial Driver

Data Sheet – FieldServer Driver – Serial – FS-8700-74 – Veeder-Root Serial Driver

More Data Sheets…

 

Need Help

 

Veeder-Root Web Site: www.veeder.com

Need more info ? Call or email us.