TAC Gateways

 

 

The TAC I/Net 2000 protocol driver is available as a client and a server. The client can poll MR devices on a MR LAN. The server can emulate MR devices on a MR LAN. The client and server drivers both support quick polling. Quick polling refers to the ability to only report changed data whereas normal polling reports all data irrespective of changes. The drivers support the basic TAC I/Net data points. Data may be collected and stored in any combinations of input and output points making it easier to move data around. Only the specified TAC I/Net type data will be stored.

 

Convert

We have module solutions which allow integration directly into TAC I/NET products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not provided on base models.

 

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Chipkin Automation Systems And TAC Gateways

1. Experience working with TAC data conversion. We have sold and installed many systems connecting TAC I/net to foreign building management systems and devices.

2. We are system integration specialists. We have worked with most of the Building Automation Systems before.

3. We provide a free CAS BACnet explorer when you integrate to a system using BACnet. This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and give you confidence should the dreaded ‘integration finger pointing’ occur.

 

Data Sheets and Manuals

Data Sheet – FieldServer Driver – Serial – FS-8700-71 – TAC I/Net 2000

Manual – FieldServer Driver – Serial – FS-8700-71 – TAC I/Net 2000

More Data Sheets

 

Need Help

TAC I/NET Web Site: www.tac.com

Need more info ? Call or email us.