ION Gateways

 

Integrate Schneider ION Power Meters into Building Management and Industrial Systems

Schneider Power Meters already come with great connectivity solutions utilizing Modbus, DNP3 and Profibus but there may be times when your project needs connectivity to some other system.

Wilmount Engineering Products Ltd representing Schneider Electric and Chipkin Automation Systems have collaborated to test and develop some template solutions for other interfaces.

Not everyone uses Modbus or DNP3. FieldServers have support for over 110 interfaces including the 600lb gorillas of the industrial control world such as Lonworks and BACnet which is the new popular Building Automation System.

We have module solutions which allow integration directly into ION Power Meter as well as the stand alone solutions shown bottom right.

 

ION 8800

ION 8800

ION 7650 and 7350

ION 6200

ION 7350 and 7330 and 7300

ION EEE Enterprise Energy Management Computer can also act as a data source for data conversion.

 

Convert

We have module solutions which allow integration directly into ION Power Meters as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not provided on base models.

 

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

 

 

Chipkin Automation Systems

1. Experience working with Power Meter data conversion. We have sold and installed many systems connecting power meters to building management and PLC systems.

2. We are system integration specialists. We have worked with most of the Building Automation Systems before.

3. We provide a free CAS BACnet explorer when you integrate to a system using BACnet. This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and it will save you pain.

 

If you liked this post;