Metasys by JCI FieldServer Gateways

Want to protect your investment in installed devices which only support N2?

We have a solution, that connects to the N2 trunks, sucks up the device points list, maps it automatically onto an appropriately named and configured BACnet objects, allows for manual customization and does this all at the click of a button then you need to see our demo of the S4 Open: BACnet-N2 Router. It is truly amazing to see how much engineering effort can be save by this automated process.
Want to add foreign devices to a N2 network ?

We have solutions that allow you, using our gateways, to make foreign devices appear as N2-Open devices. We support over 100 different protocols. Every one of them can be converted to N2. This gives you the ability to integrate a large number of fire alarm panels, gensets, HVAC equipment, sensors, PLC’s and many other devices. Data transfer can be bi-directional.

 

Convert

We have module solutions which allow integration directly into Metasys Data N2 by JCI as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Block Diagram

 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

S4 Group Solutions for Metasys N2 by JCI

Data Sheets and Manuals

FieldServer Driver – Serial – FS-8700-19 – Metasys N2 by JCI

Manual – FieldServer Driver – Serial – FS-8700-19 – Metasys N2 by JCI

Manual – FieldServer Driver – Serial – FS-8700-07 – BACnet Arcnet

Manual – FieldServer Driver – Serial – FS-8700-73 – BACnet MSTP

Manual – FieldServer Driver – Serial – FS-8704-02 – Bacnet Ethernet

Data sheet – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Manual – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Data Sheet – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

Manual – FieldServer Driver – Serial – FS-8704-06 – BACnet IP