QuickServer

 

 

FS-QS-1010-XXXX            FS-QS-1011-XXXX

 

QuickServer BAS – Cost-effective gateway built on proven FieldServer platform

QuickServer is a high-performance, fully-configurable, cost-effective Building Automation gateway for integrators to easily interface devices to networks in commercial buildings, industrial plants and campuses.

 

Two QuickServer Designs

 

FS-QS-1010 is BTL Marked and it includes two serial ports (up to 115K baud) and one Ethernet port (10/100 RJ45). This allows it to communicate serial to serial, serial to Ethernet or Ethernet to Ethernet.

 

FS-QS-1011 includes one serial port (up to 115K baud), one Ethernet port (10/100 RJ45) and one FTT-10 LonWorks port. This allow s it to communicate serial to serial, serial to Ethernet, Ethernet to Ethernet, serial to LonWorks or Ethernet to LonWorks.

 

The part number structure for the QuickServer is FS-QS-101X-XXXX. The XXXX indicates the specific model of QuickServer, indicating the drivers pre-loaded.

 

The user can preselect two BAS drivers (serial, Ethernet and/or LonWorks) to be loaded on the QuickServer at no extra charge. Additional drivers are available at extra costs.

 

Key Features:

  • Multi-configuration capability; specific configurations selectable via DIP switches or software.
  • Ability to interface up to 250 points of common BAS protocols.
  • Same firmware as our industry proven devices.
  • BACnet COV support for fast data communication while reducing traffic over a BACnet network
  • Capacity of 250 LonWorks network variables – almost 5 times more than competition – FS-QS-1011 Series
  • Flat panel mount standard, DIN rail mount option
  • Free BACnet Explorer worth $595 with purchase that include a BACnet driver.

QuickServer can configure a combination of drivers such as Modbus RTU, Modbus TCP, BACnet/IP, BACnet MS/TP, LonWorks, JCI Metasys N2 and SNMP.

Simply select a model in the chart below:

 

BACnet/IP
BACnet MS/TP
Modbus TCP Modbus RTU JCI Metasys N2 LonWorks SNMP
BACnet/IP FS-QS-1010-0285 FS-QS-1010-0237 FS-QS-1010-0104 FS-QS-1010-0122 FS-QS-1011-0131 FS-QS-1010-0333
BACnet MS/TP FS-QS-1010-0285 FS-QS-1010-0419 FS-QS-1010-0367 FS-QS-1010-0309 FS-QS-1010-0694
Modbus TCP FS-QS-1010-0237 FS-QS-1010-0030 FS-QS-1010-0117 FS-QS-1011-0154 FS-QS-1010-0248
Modbus RTU FS-QS-1010-0104 FS-QS-1010-0367 FS-QS-1010-0038 FS-QS-1011-0085 FS-QS-1010-1014
JCI Metasys N2 FS-QS-1010-0122 FS-QS-1010-0309 FS-QS-1010-0117 FS-QS-1010-0038 FS-QS-1011-0097 FS-QS-1010-0150
LonWorks FS-QS-1011-0131 FS-QS-1011-0154 FS-QS-1011-0085 FS-QS-1011-0097 FS-QS-1011-0337
SNMP FS-QS-1010-0333 FS-QS-1010-0694 FS-QS-1010-0248 FS-QS-1010-1014 FS-QS-1010-0150 FS-QS-1011-0337

 

Connections:

 

QuickServer_Serial-Ethernet_WhiteQuickServer_1011

FS-QS-1210 Series           FS-QS-1211 Series

QuickServer Enhanced – Cost-effective proven gateway accessing extensive FieldServer driver library

QuickServer, the high-performance, fully-configurable, cost-effective, proven gateway for integrators to easily interface devices to networks in commercial buildings, industrial plants and campuses, is also available in an Enhanced package. The QuickServer Enhanced offers all the rich benefits of the QuickServer BAS, but can accept up to 500 points, and comes complete with any two Serial or Ethernet drivers available from the extensive FieldServer Driver Library. RS-232 and RS-422 serial output options are also available on the QuickServer Enhanced.

 

Two QuickServer Enhanced Designs

 

FS-QS-1210 Series is the QuickServer enhanced model with Serial an Ethernet drivers. It includes two serial ports (up to 115K baud) and one Ethernet port (10/100 RJ45). This allows it to communicate serial to serial, serial to Ethernet or Ethernet to Ethernet.

 

FS-QS-1211 Series is the QuickServer enhanced model with LonWorks driver. It includes one serial port (up to 115K baud), one Ethernet port (10/100 RJ45) and one FTT-10 LonWorks port. This allow s it to communicate serial to serial, serial to Ethernet, Ethernet to Ethernet, serial to LonWorks or Ethernet to LonWorks.

 

Key Features:

  • Ability to interface up to 500 points of common BAS protocols
  • BTL Mark – FS-QS-121X Series
  • LonMark Certified – FS-QS-12X1 Series
  • BACnet COV support for fast data communication while reducing traffic over a BACnet network
  • Capacity of 500 LonWorks network variables – almost 5 times more than competition – FS-QS-12X1 Series
  • RS-232 or RS-422 serial port options
  • Multi-configuration capability; specific configurations selectable via DIP switches or software
  • External DIP switches and LED lights to aid in easy set-up and operation
  • Flat panel mount standard, DIN rail mount option
  • DIP switches to select baud rate or node ID on the fly

Simply select a model:

FS-QS-1210 Series FS-QS-1211 Series

 

 

Quickserver_KNXQuickserver Mbus

QuickServer KNX       QuickServer Mbus

 

QuickServer Fieldbus – Cost-effective proven gateway

QuickServer is a high-performance, fully-configurable, cost-effective Building Automation gateway for integrators to easily interface devices to networks in commercial buildings, industrial plants and campuses.

 

Two QuickServer Fieldbus Designs

 

KNX QuickServer Gateway from FieldServer Technologies enables data access from KNX networks to devices and networks utilizing open and proprietary protocols such as BACnet, Modbus, LonWorks, Metasys N2 by JCI, EtherNet/IP SNMP and more. QuickServer is a galvanic-isolated translator device on KNX/TP installations with control and monitoring capabilities. All EIS data types are supported, allowing communication to any kind of KNX solution devices in the installation, such as temperature sensors, shutters, light switches, actuators, alarms etc.

 

M-Bus QuickServer Gateway from FieldServer Technologies easily enables data access between M-Bus networks and devices and other networks that utilize open and proprietary protocols such as BACnet, Modbus, LonWorks, Metasys N2 by JCI, EtherNet/IP, SNMP and more.M-Bus QuickServer Gateway is configurable to act as both a Master and a Slave M-Bus device. As an M-Bus Master the number of devices supported is limited to up to 64 devices as the FieldServer provides power to the M-Bus. The M-Bus master interrogates the slave devices as the gateway acts as a Client. It will request information from the slave devices and receive and process only the expected responses.

 

Simply select a model:

KNX QuickServer Gateway M-Bus QuickServer Gateway

 