FEATURED PRODUCT

Silent Knight Fire Panel Integration

Discover Our Silent Knight Gateway!                                  240_F_30863217_90x9u7dIZJexMpPkgLRQpMlXqJN9mpgm

Our gateway allows you to integrate data from your fire alarm panels into remote systems for monitoring purposes. This way you can display fire system data on the same HMI as your operators and janitors are already watching. Fire enunciator panels often only tell you the zone. To get more info you have to go to the fire panel. Avoid this with direct integration. Our gateways can also be configured as web servers so we can web-serve the fire panel data – you get more data in front of more people without the cost of more enunciators.

Description

The Silent Knight Gateway Command (SKgwcmd) Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS-485 using Silent Knight Gateway Command (SKgwcmd) Driver protocol.  The FieldServer can emulate either a Server or Client. The Silent Knight Gateway Command driver can serve as an active client as well as emulate a Silent Knight 5820 device in server mode. The Silent Knight unit’s serial port settings are configurable. The FieldServer device can be configured to match all Silent Knight port settings.

 

The Driver Can Process the Following Commands/Queries

Grid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Chipkin Automation and Silent Knight

The serial port on the Silent Knight Unit is not addressable and the protocol does not support node identification. Therefore, only one Silent Knight unit can be connected to each port on the FieldServer.

The FieldServer Silent Knight driver was developed by Chipkin for FST – Get expert support from day 1 with Chipkin.

Easy to Deploy

Device is shipped ready for plug and play.

Chipkin stands by you – you are never alone. Real support from real people – who care, who know what they are doing and who have an exceptional reputation for service. We don’t ship boxes. We provide solutions.

Range of Conversion Solutions

Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.

 

QuickServer 1010 2x RS485 1x Ethernet
QuickServer 1011 1x RS485 1x Ethernet 1x Lonworks
QuickServer 1210 1x RS485 1xRS232 1x Ethernet
QuickServer 1211 1x RS485 1xRS232 1x Ethernet 1x Lonworks
QuickServer Fieldbus 1x RS485 1x Ethernet M-bus or KNX
FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:egProfibus, DeviceNet etcHot Standby Support
FS40 Series 8x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: egDH+, MB+, Profibus, DeviceNet etcHot Standby Support

 