Rapid Engineering Data Conversion

 

Integrate your Rapid Engineering ICS controllers into your building automation system or provide remote monitoring / control capabilities.

Our Rapid Engineering ICS driver allows communication with ICS controllers connected on a RS485 trunk. We have gateway devices which can handle from 1-12 trunks. The operational data read from each unit can be made available to any one of over 110 other protocols supported by FieldServer.  Thus, the rapid units can be monitored, controlled and scheduled by a remote system. In addition, our gateways can also be web server’s  – serving custom web pages animated / displaying real time data from the Rapid Engineering heaters.

Integration into a system allows the heaters to be controlled in a way that best suit an owner’s heating requirements and pocket providing maximum heating when required and reducing energy consumption by adopting effective schedules and control strategies. Using the CAS ICS driver you can also protect an owner’s investment in older equipment which does not have a method for integration into a building management system.

 

Convert

We have module solutions which allow integration directly into Rapid Engineering products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.

FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
Hot Standby Support
FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
Hot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Find your protocol

We have a huge list of protocols.

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Chipkin Automation and Rapid Engineering

Experience working with Rapid Engineering. CAS has visited and worked with Rapid. Rapid loaned CAS equipment for testing and continues to provide information and support. We have sold systems to Rapid and to Rapid customers.

 

Data Sheets and Manuals

Data Sheet – FieldServer Driver – Serial – FS-8705-09 – Rapid Engineering ICSI or ICSII Controller Protocol

Manual – FieldServer Driver – Serial – FS-8705-09 – Rapid Engineering ICSI or ICSII Controller Protocol

More Data Sheets

 

Need Help

Rapid Engineering Web Site: www.rapidengineering.com

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.