Integrate your Rapid Engineering ICS controllers into your building automation system or provide remote monitoring / control capabilities.
Our Rapid Engineering ICS driver allows communication with ICS controllers connected on a RS485 trunk. We have gateway devices which can handle from 1-12 trunks. The operational data read from each unit can be made available to any one of over 110 other protocols supported by FieldServer. Thus, the rapid units can be monitored, controlled and scheduled by a remote system. In addition, our gateways can also be web server’s – serving custom web pages animated / displaying real time data from the Rapid Engineering heaters.
Integration into a system allows the heaters to be controlled in a way that best suit an owner’s heating requirements and pocket providing maximum heating when required and reducing energy consumption by adopting effective schedules and control strategies. Using the CAS ICS driver you can also protect an owner’s investment in older equipment which does not have a method for integration into a building management system.
Convert
We have module solutions which allow integration directly into Rapid Engineering products as well as the stand alone solutions shown bottom right.
Range of Conversion Solutions
Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.
| FS20 Series | 1x RS232/485 | 1x Ethernet | 1x Lonworks | |
| FS25 Series | 2x RS232/485 | 1x Ethernet | ||
| FS30 Series | 2x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support:eg Profibus, DeviceNet etc Hot Standby Support |
| FS40 Series | 10x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc Hot Standby Support |
| SlotServer | 1x RS232/485 | 1x Ethernet | 1x Lonworks | For Rockwell ControlLogix 5600 |
Lonworks and Fieldbus are options not proviced on base models.
Find your protocol
We have a huge list of protocols.
| Web
Building automation Other Categories
|
Industial
|
Industial |
Block Diagram
FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.
Chipkin Automation and Rapid Engineering
Experience working with Rapid Engineering. CAS has visited and worked with Rapid. Rapid loaned CAS equipment for testing and continues to provide information and support. We have sold systems to Rapid and to Rapid customers.
Data Sheets and Manuals
– Data Sheet – FieldServer Driver – Serial – FS-8705-09 – Rapid Engineering ICSI or ICSII Controller Protocol
– Manual – FieldServer Driver – Serial – FS-8705-09 – Rapid Engineering ICSI or ICSII Controller Protocol
Need Help
Rapid Engineering Web Site: www.rapidengineering.com
Need more info ? Call or email us.