Quadlogic Data Conversion

Quadlogic meters support a Modbus RTU Interface using RS232/RS485. No other protocol is supported. We have solutions which can map the meter data onto other protocols so you can monitor power and energy data using other systems. Our solutions allow multiple trunks of meters / closets to be connected to a single gateway. Trunks can have multiple units installed. Our Modbus solutions also allow multi-master configurations, so if you already have one system talking to the meters using Modbus RTU you can still add a gateway and have both our gateway and the other system act as masters. We can also provide an embedded web server with pages that display current data.

 

Convert

We have module solutions which allow integration directly into Quadlogic products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.

FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
Hot Standby Support
FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
Hot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

 

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Chipkin Automation and Quadlogic

CAS has invested time to work with QMC, the British Columbia distributor of Quadlogic products to test and prove the mappings from the QLC meters. Testing was performed using QMC’s calibration test bench.

 

Data Sheets and Manuals

Data Sheet – FieldServer Driver – Serial – FS-8700-01 – Modbus RTU

Manual – FieldServer Driver – Serial – FS-8700-01 and FS8700-08 – Modbus RTU and ASCII

Data Sheet – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Manual – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Data Sheet – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

– Manual – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

More Data Sheets

 

Need Help

Quadlogic Web Site: www.quadlogic.com

Need more info ? Call or email us.