BACnet and Modbus Gateways

Block Diagram

Using a gateway you can integrate non-bacnet devices into your system such a fire alarm panels, lighting systems, PLCs etc.

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

Flavors of Bacnet and Modbus

FieldServer’s support: BACnet IP, MSTP, 802.3, Arcnet, Modbus RTU, Modbus ASCII, Modbus+, Modbus/TCP. A single gateway can support many protocols.

 

Free Explorer and Guide

When you purchase a gateway from CAS which includes a BACnet driver then we include a full license to the CAS BACnet Explorer. You can use the explorer to test / prove / document the BACnet interface. Some limitations apply to this offer and it is a limited time offer. Read more about the CAS BACnet Explorer. You can purchase this guide for $20 from amazon.com or download the BACnet For Field Technicians for free.

 

Range of Conversion Solutions

Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.

FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus,
DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Chipkin Automation and Bacnet

Chipkin Automation Systems has attended the BACnet plugfest in 2009, 2007 and 2006 to test its Bacnet Software and tools.

 

Data Sheets and Manuals

Manual – FieldServer Driver – Serial – FS-8700-07 – BACnet Arcnet

Manual – FieldServer Driver – Serial – FS-8700-73 – BACnet MSTP

Manual – FieldServer Driver – Serial – FS-8704-02 – Bacnet Ethernet

Data sheet – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Manual – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Data Sheet – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

Manual – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

Data Sheet – FieldServer Driver – Serial – FS-8700-08 – Modbus ASCII

Data Sheet – Serial – FS-8700-15 – Modbus Daniels

Manual – Serial – FS-8700-15 – Modbus Daniels

Data Sheet FieldServer Driver – Serial – FS-8700-33 – Modbus Omniflow

Manual – FieldServer Driver – Serial – FS-8700-33 – Modbus Omniflow

Data Sheet – FieldServer Driver – Fieldbus – FS-8700-02 – Modbus Plus

Manual FieldServer Driver – Fieldbus – FS-8700-02 – Modbus Plus

Data Sheet – FieldServer Driver – Serial – FS-8700-01 – Modbus RTU

Manual – FieldServer Driver – Serial – FS-8700-01 – Modbus RTU

Data Sheet – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Manual – FieldServer Driver – Ethernet – FS-8704-03 – Modbus TCP

Data Sheet – FieldServer Driver – Serial – FS-8700-32 – Modbus Tek-Air

Manual – FieldServer Driver – Serial – FS-8700-32 – Modbus Tek-Air

More Data Sheets…

 

Find your protocol

We have a huge list of protocols.

Web

Building automation

Other Categories

Industial

Industial

 

Need Help

Bacnet Web Site: www.bacnet.org

Need more info ? Call or email us.

CAS is a member of BACnet International

BACnet Internatl member of logo

 

 

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

If you liked this post;
  • Please consider subscribing to our RSS feed