BACnet-Data-Conversion

Data / Protocol Converters

  • Convert BACnet Data to over 110 other protocols using FieldServers
  • We sell, support, configure and develop custom drivers for FieldServer
  • Convert to/from Lonworks, Metasys N2 Open by JCI, Modbus, Rockwell, GE, Omron, HVAC, UPS, Cummins, Kohler, Power Meters, ION, PLCS, Many Fire Panels such as Simplex, Notifier, Siemens …. And many more
  • We can be a client, server and both client and server.

 

Free Explorer and Guide

When you purchase a gateway from CAS which includes a BACnet driver then we include a full license to the CAS BACnet Explorer. You can use the explorer to test / prove / document the BACnet interface. Some limitations apply to this offer and it is a limited time offer. Read more about the CAS BACnet Explorer.

You can purchase this guide for $20 from amazon.com or download the BACnet for Field Technicians for free.

 

Flavors of Bacnet

FieldServer’s support,

BACnet IP,

MSTP,

802.3,

Arcnet

 

Convert

We have module solutions which allow integration directly into Bacnet products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus,
DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

 

Block Diagram

Using a gateway you can integrate non-bacnet devices into your system such as fire alarm panels, lighting systems, PLCs etc.

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

S4 Group Solutions for Metasys N2 by JCI

S4 Open: BACnet-N2 Router

Typical Applications would be to bring data from the Metasys® N2 by JCI network into BACnet-based enterprise applications, energy management applications, or adding best-of-breed BACnet-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy Metasys® by JCI installations.

– S4 Open: BACnet-N2 Router Product Capabilities

Chipkin Automation and Bacnet

Chipkin Automation Systems has attended the BACnet plugfest in 2009, 2007 and 2006 to test its Bacnet Software and tools.

 

Data Sheets and Manuals

Manual – FieldServer Driver – Serial – FS-8700-07 – BACnet Arcnet

Manual – FieldServer Driver – Serial – FS-8700-73 – BACnet MSTP

Manual – FieldServer Driver – Serial – FS-8704-02 – Bacnet Ethernet

Data sheet – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Manual – FieldServer Driver – Serial – FS-8700-16 – Bacnet PTP

Data Sheet – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

Manual – FieldServer Driver – Serial – FS-8704-06 – BACnet IP

Data Sheet – CAS 2500-04 BACnetIP Data Client

Data Sheet – CAS 2500-04-UL BACnetIP Data Client

Data Sheet – CAS 2500-05 BACnetEth Data Client

Data Sheet – CAS 2500-05-UL BACnetEth Data Client

Data Sheet – CAS 2500-06 BACnet MSTP Data Clien

Data Sheet – CAS 2500-06-UL BACnet MSTP Data Client

More Data Sheets…

 