Chipkin.com

OPC Data Conversion

Up one level

 

The FieldServer OPC Server installs on a windows computer and functions in the same way as all other OPC Servers in its ability to serve data to clients on the same or networked computers. However, its data source is a FieldServer connected via an Ethernet network. The FieldServer can be loaded with any FieldServer drivers (over 100 protocols supported) and can access data from Fire Panels, HVAC equipment, PLCs and many other devices.

The S4 Group: N2 OPC Server is a product aimed at making JCI Metasys N2 by JCI data available as OPC data.  When connected to a N2 network , it scans all the devices and automates the mapping of all data points to OPC data.

Block diagrams for both solutions are show below.

 

Convert

 

We have module solutions which allow integration directly into OPC products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

 

    FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
    FS25 Series
    2x RS232/485 1x Ethernet
    FS30 Series
    2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
    Hot Standby Support
    FS40 Series
    10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
    Hot Standby Support
    SlotServer
    1x RS232/485
    1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

    Lonworks and Fieldbus are options not proviced on base models.

 

Find your protocol

 

We have a huge list of protocols.

 

Block Diagram

 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

The S4 Open: OPC-N2 Router offers flexibility and cost savings when integrating legacy Metasys® N2 by JCI networks to Open Systems. The OPC-N2 Router avoids costly replacement or re-engineering of existing devices on legacy N2 buses. Typical Applications would be to bring data from the Metasys® N2 by JCI network into OPC-based enterprise applications, energy management applications, or adding best-of-breed OPC-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy Metasys® by JCI installations.

 

- S4 Open: OPC-N2 Router Product Capabilities

 

 

Data Sheets and Manuals

 

- Data Sheet - FieldServer Driver - Serial - FS-8707-06 - FST OPC Server for FieldServers

- Manual - FieldServer Driver - Serial - FS-8707-06 - FST OPC Server for FieldServers

More Data Sheets...

 

Need Help

 

OPC Web Site: www.opcfoundation.org

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.