FS-B2010

Feature rich protocol translator bridge enables data transfer between serial and Ethernet protocols. An extensive library of drivers provides easy interoperability between a variety of devices used in building automation, HVAC, fire and process control industries.

Serial – Ethernet

FieldServer Bridge is a protocol translator gateway which enables devices using one protocol to communicate with devices using another protocol. An example is a fire alarm panel using a proprietary manufacturer s protocol needing to supply alarm information to a building automation system. In a single, comprehensive package the FS-Bridge provides the hardware and software necessary for this translation. The FS-B2010 includes serial (RS-232/RS-485) and Ethernet (10BaseT) connectors to interface to the devices. Configuration files can be downloaded via the serial port or Ethernet port. All the necessary software and instructions for configuration are supplied with the FS-Bridge. FieldServer Technologies also offers fee based configuration services. FS-Bridges are also available for various fieldbuses or multiple port applications.

Specifications

Field Connections

  • Ethernet Port
    – 10baseT RJ45 connector
  • Serial Port
    – RS-232/RS-485 selectable
    – Up to 115K baud
    – RJ45 connector (RS-232)
    – Terminal connector (RS-485)

Host PC Connections (for Configuration)

  • Ethernet 10baseT
  • RS-232/RS-485 selectable

LED Indicators

  • Power, Run, System Error, Configuration Error
  • Ethernet connection – Tx/Rx communication
  • RS-232/RS-485 – Tx/Rx communication

Other

  • OPC server available
  • Configuration utility
  • Diagnostic utility
  • System integration services available

Power Requirements

  • 9-30 VDC
  • 2.5 watts

Environment

  • Operating temperature: 0-60oC (32-144oF)
  • Relative humidity: 10-95% RH non-condensing

Physical Dimensions

  • 3.9 x 3.9 x 2 in. (WxDxH) (100 x 100 x 50 mm)
  • 0.4 lbs (0.8 Kg)

Mounting Options

  • Desktop
  • Wall
  • DIN Rail

Approvals

  • UL 916
  • FCC – Tested to comply with FCC part 15
  • CE Marked

 

Manuals and Datasheets

FS-B2010 Datasheet

FS-B2010 Manual

 

FS-B2011

Feature rich protocol translator enables data transfer between LONWORKS® protocol and an extensive library of other serial and Ethernet protocols used in a building automation, HVAC, fire and process control industries

LonWorks® – Serial – Ethernet

FieldServer LONWORKS® Gateway is a protocol translator which enables devides using legacy protocols to communicate with LONWORKS networks. An example is a fire alarm panel using a proprietary manufacturer’s protocol needing to supply alarm information to a LONWORKS network. In a single, comprehensive package the FSBridge provides the hardware and software necessary for this translation. In addition to the LONWORKS connector, the FS-B2011 includes a serial (RS-232 or RS-485) and Ethernet (10BaseT) connector. Configuration files can be downloaded via the serial or Ethernet port. All the necessary software and instructions for configuration are provided with the FS-B2011. FieldServer Technologies also offers fee based configuration services. Other FieldServers are available for other fieldbuses or for multiple port applications.

Specifications

Field Connections

  • LonWorks®
    • FTT-10 twisted pair
    • 1000 Network variable capability
    • UNVT or SNVT variable support
    • Explicit (Polled Mode) or Implicit (Bound Mode) Addressing
    • LonMark Profiles
    • SPID: 80:00:95:46:00:84:04:02
    • Profile:
      • 0000 – Node object (1)
      • 0001 – Open Loop Sensor Object (20)
      • 0003 – Open Loop Actuator Object (20)
  • Ethernet Port
    • 10BaseT RJ45 connector
  • Serial Port
    • RS-232/RS-485 selectable
    • Up to 115K baud
  • Drivers
    • Drivers available for a wide range of Ethernet and serial protocols – check driver informationsheet

Host PC Connections (for Configuration)

  • Ethernet 10BaseT
  • RS-232/RS-485 selectable

LED Indicators

  • Power, Run, System Error, Configuration Error
  • Ethernet connections– Tx/Rx communication activity
  • RS-232/RS-485 – Tx/Rx communication activity

Power Requirements

  • 24 VAC Floating (voltage variation + 10%)
  • 9-30 VDC @ 8W

Others

  • Service Pin for LONWORKS® Node identification
  • OPC server available
  • Configuration utility
  • Diagnostic utility
  • System integration services available

Environment

  • Operating temperature: 0-60oC (32-144oF)
  • Relative humidity: 10-95% RH noncondensing

Physical Dimensions

  • 3.9 x 3.9 x 2 in. (100 x 100 x 50 mm)
  • 0.8 lbs (0.36 Kg)

Mounting Options

  • Desktop
  • Wall
  • DIN Rail

Approvals

  • UL/ULC 916
  • FCC part 15
  • CE Marked
  • LonMark Certified
  • OPC Self Certified
  • DNP3 Certified

FS-B2510

A protocol translator gateway enables data transfer between serial and Ethernet protocols. An extensive library of driv- ers provides easy interoperability between a variety of de- vices used in building automation, HVAC, fire and process control industries.

 

Dual Serial – Ethernet

 

The FS-B2510 FieldServer Gateway provides two serial ports and one Ethernet port making it ideal for interfacing either two serial devices or a serial to Ethernet connection. An example is a fire alarm panel using a proprietary manufacturer’s protocol needing to supply alarm information to a building automa- tion system. In a single, comprehensive package the FS-B2510 provides the hardware and software necessary for this translation.  The FS-B2510 includes two serial (switchable RS-232/RS-422/RS-

485) ports and an Ethernet (10/100BaseT) connector to interface to the devices. Configuration files can be downloaded via Ethernet port. All the necessary software and instructions for configuration are supplied with the FieldServer. FieldServer Technologies also offers fee based configuration services.

Specifications

Field Connections

  • Ethernet Port 2
    – 10BaseT, 100BaseTX RJ45 (auto-sensing)
  • Serial Port 4
    ? RS-232/RS-422/RS-485 switchable (soft- ware)? Up to 115200 baud? DB9 connector
  • Drivers
    – Drivers available for a wide range of Ethernet and serial protocols

Host PC Connections(for Configuration)

  • Ethernet 10BaseT

LED Indicators

  • Ethernet connection – Tx/Rx communication activity
  • Serial 1, Serial 2, CPU communication activity

Environment

  • Operating temperature: -40 to 85oC (-40 to185oF)
  • Relative humidity: 10-95% RH non-condensing

Power Requirements

  • 5V – 30V DC, 500 mA
  • 120VAC to 9VDC power supply is provided

Other

  • Configuration utility
  • Diagnostic utility
  • System integration services available

Physical Dimensions

  • 4.55 x 4.50 x 1.35 in. (LxWxD) (11.56 x 11.68 x 3.43 cm)
  • 0.4 lb (0.18 Kg)

 

Mounting Options

  • Desktop
  • Wall
  • DIN Rail

Approvals

  • UL 916
  • CE EN55022, EN 55024
  • FCC Class A, Part 15

FS B3510

This protocol translator/gateway provides a wealth of features to enable data transfer between different devices and networks utilizing serial, Ethernet or LonWorks protocols. The extensive library of FieldServer drivers provides easy interoperability with devices and networks used in building automation, HVAC, fire and process control industries.

 

Serial – Ethernet – LonWorks

The FS-B3510 is one of the FS-X30 Series FieldServers designed to meet the needs of system integrators in designing a complete interoperable system. The FS-B30 Series brings together the powerful FieldServer driver library with state-of-the-art gateway design. This FieldServer includes four serial connections (two RS-232, two RS-485), two 10/100BaseT Ethernet ports, and a LonWorks port. The multiport design allows for serial-to-serial interfaces or interface from mulitple serial products to an Ethernet or LonWorks network. The two Ethernet ports enable the integrator to connect a PC to download configuration changes without disturbing the system connections and without the additional cost of an external hub. The second Ethernet port is also used for the optional hot standby for redundant system requirements.

Specifications

Field Connections

  • Ethernet Port 2
    – 10baseT RJ45 connector
  • Serial Port 4
    1 – RS-232 with RJ45 connector
    1 – RS-232 with DB9 connector
    2 – RS-485 terminal connectors
    Up to 115K baud
  • LonWorks – 1
    – FTT-10 twisted pair
    – 1000 Network variable capability
  • Drivers
    – Drivers available for a wide range of Ethernet and serial protocols

LED Indicators

  • Power, Run, System Error, Configuration Error, Node offline
  • Ethernet connection – Tx/Rx communication
  • RS-232/RS-485 – Tx/Rx communication

Environment

  • Operating temperature: 0-65oC (32-149oF)
  • Relative humidity: 10-95% RH non-condensing

Power Requirements

  • 24 VDC
  • 12-48 VDC @ 12 watts

Other

  • Configuration/Diagnostic utilities
  • Compact Flash and I/O ports for specific driver requirements
  • Base system has 1000 point capability (upgradeable to 10,000 points)

Physical Dimensions

  • 6.3 x 5.4 x 2.0 in. (16.0 x 13.7 x 5.0 cm)
  • 2.5 lbs (1.5 Kg)

Mounting Options

  • Desktop
  • Wall
  • DIN Rail

Approvals

  • UL 916
  • FCC – Tested to comply with FCC part 15
  • CE Marked

Options

  • Memory upgrade for additional data points
  • Custom Configuration Services

 

FS-B4010

A 10-serial, 2-Ethernet port, protocol translator gateway enables data transfer between serial and Ethernet proto- cols. An ISA slot allows additional driver cards. An ex- tensive library of drivers provides easy interoperability between a variety of devices used in building automa- tion, HVAC, fire and process control industries

 

Serial – Ethernet

 

The FieldServer is a protocol translator/gateway which enables devices using one protocol to com- municate with devices using another protocol. An example is a fire alarm panel using a proprietary manufacturer’s protocol needing to supply alarm information to a building automation system.  In a single, comprehensive package the FieldServer provides the hardware and software necessary for this translation. The FS-B4010 Series includes eight RS-232 ports, two RS-485 ports, two Ethernet (10BaseT) ports to interface to the devices. In addition there is an ISA card slot for special driver adapter cards such as LONWORKS®, DH+, Profibus, ControlNet, etc.  All the necessary software and instructions for configuration are supplied with the FieldServer. FieldServer Technologies also offers fee based configuration services. FieldServers are available for various fieldbuses.

Specifications

Field Connections

  • Ethernet Port 2
    – Qty 2 – 10BaseT RJ45 connector
  • Serial Port 4
    ? Qty 8 RS-232 ports, RJ45 connector? Qty 2 RS-485 ports, terminal connector? Up to 115K baud
  • ISA Card slot for additional adapters
    – DH+, ControlNet, Profibus, LONWORKS®, Modbus Plus, Arcnet
  • Drivers
    – Drivers available for a wide range of Ethernet and serial protocols

Host PC Connections (for Configuration)

  • Ethernet 10BaseT
  • RS-232 or RS-485

LED Indicators

  • Power, Run, System Error, Configuration Error, Node offline
  • Port connections – Tx/Rx communication activity

Environment

  • Operating temperature: 0-60oC (32-144oF)
  • Relative humidity: 10-95% RH non-condensing

Power Requirements

  • 120/220 VAC, 50/60 Hz, 1 amp

Other

  • Hot standby option
  • Configuration utility
  • Diagnostic utility
  • System integration services available

Physical Dimensions

  • 7.5 x 12.0 x 2.2 in. (WxDxH) (19.1 x 30.5 x 5.6 cm)
  • 5.0 lbs (3.0 Kg)

Mounting Options

  • Desktop
  • Wall
  • DIN Rail

Approvals

  • UL 916
  • CE Marked

Manuals and Datasheets

 –FS-B2011 Datasheet

 –FS-B2011 Manual