Metasys N2 by JCI Data Conversion
Up one level
Want to protect your investment in installed devices which only support N2?
We have a solution, that connects to the N2 trunks, sucks up the device points list, maps it automatically onto an appropriately named and configured BACnet objects, allows for manual customization and does this all at the click of a button then you need to see our demo of the S4 Open: BACnet-N2 Router. It is truly amazing to see how much engineering effort can be save by this automated process.
Want to add foreign devices to a N2 network ?
We have solutions that allow you, using our gateways, to make foreign devices appear as N2-Open devices. We support over 100 different protocols. Every one of them can be converted to N2. This gives you the ability to integrate a large number of fire alarm panels, gensets, HVAC equipment, sensors, PLC's and many other devices. Data transfer can be bi-directional.
Convert
We have module solutions which allow integration directly into Metasys Data N2 by JCI as well as the stand alone solutions shown bottom right.
Range of Conversion Solutions
Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
| FS20 Series | 1x RS232/485 | 1x Ethernet | 1x Lonworks | |
| FS25 Series |
2x RS232/485 | 1x Ethernet |
||
| FS30 Series |
2x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support:eg Profibus, DeviceNet etc Hot Standby Support |
| FS40 Series |
10x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc Hot Standby Support |
| SlotServer |
1x RS232/485 |
1x Ethernet | 1x Lonworks | For Rockwell ControlLogix 5600 |
Lonworks and Fieldbus are options not proviced on base models.

Find your protocol
We have a huge list of protocols.
| Web
Building automation Other Categories
|
Industial
|
Industial |
Block Diagram
FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.
S4 Group Solutions for Metasys N2 by JCI
S4 Open: BACnet-N2 Router
Typical Applications would be to bring data from the Metasys® N2 by JCI network into BACnet-based enterprise applications, energy management applications, or adding best-of-breed BACnet-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy Metasys® by JCI installations.
- S4 Open: BACnet-N2 Router Product Capabilities
S4 Open: N2 Switch
The N2 Switch avoids costly replacement or re-engineering of existing devices on the legacy N2 buses. A typical application would be replacing multiple legacy Companion / Facilitator panels with a single NAE supervisory controller.
- S4 Open: N2 Switch Product Capabilities
S4 Open: OPC-N2 Router
The OPC-N2 Router automatically discovers all N2 devices on each Downstream N2 Network and publishes the devices, and their associated points, onto the Upstream N2 and OPC IP interfaces. Typical Applications would be to bring data from the JCI N2 network into OPC-based enterprise applications, energy management applications, or adding best-of-breed OPC-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy JCI N2 installations
- S4 Open: OPC-N2 Router Product Capabilities
Chipkin Automation Systems
1. Experience working with TAC data conversion. We have sold and installed many systems connecting N2 systems to foreign building management systems and devices.
2. We are system integration specialists. We have worked with most of the Building Automation Systems before.
3. We provide a free CAS BACnet explorer when you integrate to a system using BACnet. This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and give you confidence should the dreaded ‘integration finger pointing’ occur.
Data Sheets and Manuals
- FieldServer Driver - Serial - FS-8700-19 - Metasys N2 by JCI
- Manual - FieldServer Driver - Serial - FS-8700-19 - Metasys N2 by JCI
- Manual - FieldServer Driver - Serial - FS-8700-07 - BACnet Arcnet
- Manual - FieldServer Driver - Serial - FS-8700-73 - BACnet MSTP
- Manual - FieldServer Driver - Serial - FS-8704-02 - Bacnet Ethernet
- Data sheet - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP
- Manual - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP
- Data Sheet - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
- Manual - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
Need Help
JCI Web Site: www.jci.com
Need more info ? Call or email us.
Metasys® as used in this document is a trademark of Johnson Controls, Inc.