Integrate ION Power Meters by Schneider Electric
Up one level>
Integrate Schneider ION Power Meters into Building Management and Industrial Systems
Schneider Power Meters already come with great connectivity solutions utilizing Modbus, DNP3 and Profibus but there may be times when your project needs connectivity to some other system.
Wilmount Engineering Products Ltd representing Schneider Electric and Chipkin Automation Systems have collaborated to test and develop some template solutions for other interfaces.
Not everyone uses Modbus or DNP3. FieldServers have support for over 110 interfaces including the 600lb gorillas of the industrial control world such as Lonworks and BACnet which is the new popular Building Automation System.
We have module solutions which allow integration directly into ION Power Meter as well as the stand alone solutions shown bottom right.
ION 8800
ION 8800
ION 7650 and 7350
ION 6200
ION 7350 and 7330 and 7300
ION EEE Enterprise Energy Management Computer can also act as a data source for data conversion.
Convert
We have module solutions which allow integration directly into ION Power Meters as well as the stand alone solutions shown bottom right.
Range of Conversion Solutions
Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
| FS20 Series | 1x RS232/485 | 1x Ethernet | 1x Lonworks | |
| FS25 Series | 2x RS232/485 | 1x Ethernet | ||
| FS30 Series | 2x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support:eg Profibus, DeviceNet etc Hot Standby Support |
| FS40 Series | 10x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc Hot Standby Support |
| SlotServer | 1x RS232/485 | 1x Ethernet | 1x Lonworks | For Rockwell ControlLogix 5600 |
Lonworks and Fieldbus are options not proviced on base models.

Find your protocol
We have a huge list of protocols.
| Web
Building automation Other Categories
|
Industial
|
Industial |
Block Diagram
FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.
Chipkin Automation Systems
1. Experience working with Power Meter data conversion. We have sold and installed many systems connecting power meters to building management and PLC systems.
2. We are system integration specialists. We have worked with most of the Building Automation Systems before.
3. We provide a free CAS BACnet explorer when you integrate to a system using BACnet. This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and it will save you pain.
Data Sheets and Manuals
- Data Sheet - FieldServer Driver - Serial - FS-8700-01 - Modbus RTU
- Manual - FieldServer Driver - Serial - FS-8700-01 and FS8700-08 - Modbus RTU and ASCII
- Data Sheet - FieldServer Driver - Ethernet - FS-8704-03 - Modbus TCP
- Manual - FieldServer Driver - Ethernet - FS-8704-03 - Modbus TCP
- Data Sheet - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
- Manual - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
Need Help
ION Power Meter Web Site: http://www.pwrm.com/products/
Need more info ? Call or email us.
Metasys® as used in this document is a trademark of Johnson Controls, Inc.