FS-8704-07 - Allen Bradley CSP

Up one level

FieldServer Driver - Ethernet

FS-8704-07

Allen Bradley CSP

Description

This driver implements the Allen Bradley TCP/IP protocol, also commonly referred to as the Allen Bradley CSP protocol.

 

Formal Driver Type

Ethernet

Client or Server

 

Connection Information

Connection type:

Ethernet

Ethernet Speeds Supported

10Base-T, 100Base-T[1]

 

Devices tested

Device

Tested (FACTORY, SITE)

SLC5/05 Processor

Factory

WonderWare

Site

Connection configurations

 


Communications functions - Supported functions at a glance:

Data Types Supported

FieldServer Data Type

Description (File Type)

N

INTEGER

B

BINARY

F

FLOAT

O

OUTPUT

I

INPUT

T

TIMER

S

STATUS

Read Operations supported

Allen Bradley commands can be specified directly using the AB_Command map descriptor field, or can be implied using the Node field PLC_Type. The AB_Command will override any PLC_Type specifiers.

 

Command

AB_Command

PLC_Type

File_Type

FieldServer as a Client

Unprotected Read

Unprotected

-

All file types

Protected Typed Logical Read

Protected_Typed_

Logical

-

All file types

Typed Read

Typed

-

All file types

Protected Typed Logical Read

-

SLC5

N, F, B, I, O

Word Range Read

-

PLC3/PLC5

N, F, B

FieldServer as a Server

Unprotected Read

Not Used

Not Used

All file types

Protected Typed Logical Read

Not Used

Not Used

N, F, B, I, O

Word Range Read

Not Used

Not Used

N, F, B

         

 

Write Operations supported

Command

AB_Command

PLC_Type

File_Type

FieldServer as a Client

Unprotected Write

Unprotected

-

All file types

Typed Write

Typed

-

All file types

Protected Typed Logical Write

-

SLC5

N, F, B

Word Range Write

-

PLC5

N

Typed Write

-

PLC5

F

Read Modify Write

-

PLC5

B

Word Range Write

-

PLC3

N, F

Bit Write

-

PLC3

B

FieldServer as a Server

Unprotected Write

Not Used

Not Used

All file types

Protected Typed Logical Write

Not Used

Not Used

N, F, B

Word Range Write

Not Used

Not Used

N

Typed Write

Not Used

Not Used

F

Read Modify Write

Not Used

Not Used

B

Word Range Write

Not Used

Not Used

N, F

Bit Write

Not Used

Not Used

B

 

Unsupported Data Types

Data Type

Description (File Type)

C

Counter

ST

ASCII String

T

Timer

 

 


Revision History

Date

Resp

Format

Driver Ver.

Doc.

Rev.

Comment

4/15/03

 

 

 

 

Created DFS

4/15/03

 

 

 

 

Updated DFS

5/12/03

DBW

 

1.00

1

Cleaning up DFS

7/24/03

JD

 

1.00

2

Releasing

9/26/03

JD

 

1.00

3

Minor edits.

5/6/04

Meg

Meg

1.00

4

Updated formatting.  Added connection diagram.  Added new revision table.

6/14/04

JD

 

1.00

5

Releasing

8/27/04

Meg

Meg

1.00

6

Updated Ethernet connection information – DUR0416.

12/27/04

Meg

Meg

1.00

7

Minor changes to table formatting.  Removed alphanumeric characters from version numbering.

12/30/04

JD

 

1.00

8

Releasing

 