Up one level

 

 
  Text Box: Driver Version:	1.00

FieldServer Driver

FS-8700-32

Modbus Tek-Air

Description

The Tek-Air Modbus RTU driver allows the FieldServer to transfer data to and from Tek-Air devices over either RS-232 or RS-485 using the Enhanced Tek-Air Modbus RTU protocol. Modbus_Tekair is the same as Modbus_RTU, except that it has the ability to concentrate the bytes of data in the packet to create floating point values. The order in which the bytes are combined and the address range used was developed specifically for the Tek-Air/Modbus interface. To accommodate this, the driver must be configured to poll using odd numbered addresses as two integer registers are used for every floating point value. If this value is stored in a floating point data array, it will be retrievable in the correct format on the Server side. Note that the Tekair "Double" data type is not supported.

 

Fieldserver Mode

Nodes

Comments

Client

1

Only 1 client node allowed on Multidrop systems

Server

254

Actual electrical loading may reduce number of usable server nodes

 

Formal Driver Type

Serial

Client or Server

 

Connection Information

Connection type:

RS-232 or RS-485 (Two wire, Half-Duplex)

Baud Rates:

300; 600; 1200; 2400; 4800; 9600; 19200; 28800; 38400 Baud

Data Bits:

7,8

Stop Bits:

1,2

Parity:

Odd, Even, None

Multidrop Capability

Yes

 

Devices tested

Device

Tested (FACTORY, SITE)

SmartLab Controller

Site


Connection configurations

 

Connection Notes

The actual amount of stations on a network may be limited due to electrical loading limitations.

 


Communications functions - Supported functions at a glance:

Data Types Supported

FieldServer Data Type

Description (or Device Data Type)

Analog Input

Analog Input Registers

Digital Input

Discrete Input Registers

Analog Register

Input and Output Registers

Digital Register

Input and Output Registers

Analog Output

Analog Output Registers

Digital Output

Discrete Output Registers

Read and Write Operations supported

FieldServer as a Client

FieldServer as a Server

Read Analog Status:

Provide Analog Status:

Read Output Registers (4xxxx)

Read Input Registers (3xxxx)

Provide Output Registers (4xxxx)

Provide Input Registers (3xxxx)

Read Binary Status:

Provide Binary Status:

Read Discrete Output Status (0xxxx)

Read Discrete Input Status (1xxxx)

Provide Discrete Output Status (0xxxx)

Provide Discrete Input Status (1xxxx)

Write Analog Setpoints:

Accept Analog Setpoints:

Preset Single Register (4xxxx)

Preset Multiple Registers (4xxxx)

Accept Preset Single Register (4xxxx)

Accept Preset Multiple Registers (4xxxx)

Write Binary Commands:

Accept Binary Commands:

Force Single Coil (0xxxx)

Force Multiple Coils (0xxxx)

Accept Force Single Coil (0xxxx)

Accept Force Multiple Coils (0xxxx)

 

Unsupported Functions and Data Types

Function

Reason

Programming messages

FieldServer is a data transfer device, and as such, programming messages are not required

 

Unsupported Devices or Protocol Options

Device

Details

TBD

TBD


Revision History

 

THIS PAGE INTENTIONALLY LEFT BLANK