FS-8700-127 - Hanning & Kahl HCS-R

Up one level

Text Box: Driver Version:	1.00

 

FieldServer Driver

FS-8700-127

Hanning & Kahl HCS-R

 

Description

The Hanning & Kahl HCS-R driver allows the transfer of data from devices over RS-232 HCS-R protocol. Data is read from HCS-R and current data stored in a specified memory area.  The driver can store the data with its loop data status distinct memory areas depending on whether the data is on loop or from loop.  The driver is based on section 10.5 of Hanning & Kahl - part number 40801121.  The FieldServer can act as a Client or Server.

Fieldserver Mode

Nodes

Comments

Client

1

Only 1 virtual client per port allowed on multidrop systems,

Server

1

This is a protocol limit.

Formal Driver Type

Serial

Client or Server

Compatibility Matrix: Some devices may require a RS-485/RS-232 Converter

FieldServer Model

Compatible with this driver

FS-x2010

Yes

FS-x2011

Yes

FS-x30

Yes

FS-x40

Yes

Connection Information

Connection type:

RS-232

Baud Rates*

9600 (Vendor limitation)

Data Bits*

8 (Vendor limitation)

Stop Bits:*

1 (Vendor limitation)

Parity:*

None (Vendor limitation)

Multidrop Capability*

Yes

 

Devices tested

Device

Tested (FACTORY, SITE)

HCS-R-R" - part # "44.745.033

Site

 

Connection configurations

 

Hardware Connection Tips / Hints

1. Loop back RTS CTS if it is required by the other device.

 

Communications functions - Supported functions at a glance:

Data Types Supported

FieldServer Data Type

Description (or Device Data Type)

Digital Input

Data bits

Loop number and loop Status

Read Operations supported

FieldServer as a Client

FieldServer as a Server

 

 

Poll ( including Sync and Acknowledge)

Response along with loop number and status

Write (Control) Operations supported

FieldServer as a Client

FieldServer as a Server

N/A

N/A

Special Operations supported

FieldServer as a Client

FieldServer as a Server

N/A

N/A

Unsupported Functions and Data Types

Function

Reason

None

 

Unsupported Devices or Protocol Options

Device

Details

none

 


Revision History

 

 

THIS PAGE INTENTIONALLY LEFT BLANK