FS-8700-65 – Silent Knight Gateway Command

FieldServer Driver – Serial

FS-8700-65

Silent Knight

Gateway Command

(SKgwcmd)

Description

The Silent Knight Gateway Command (SKgwcmd) Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS-485 using Silent Knight Gateway Command (SKgwcmd) Driver protocol.  There are eight RS-232 and two RS-485 ports standard on the FieldServer.  The FieldServer can emulate either a Server or Client.

The Silent Knight Gateway Command driver can serve as an active client as well as emulate a Silent Knight 5820 device in server mode.

The Silent Knight unit’s serial port settings are configurable. The FieldServer device can be configured to match all Silent Knight port settings.

The driver can process the following commands / queries

 

o General System Status

o System Trouble Status

o General Zone Status

o Expanded Zone Status

o Zone Description

o Output Group Status

o Output Group Description

o Point Status

o Point Description

o Time Status

o gateway Version

o Disable Point

o Enable Point

o Reset Alarms

o Silence

o Time Synch

The serial port on the Silent Knight Unit is not addressable and the protocol does not support node identification. Therefore, only one Silent Knight unit can be connected to each port on the FieldServer.

 

Formal Driver Type

Serial

Client or Server

 

Compatibility Matrix

FieldServer Model Compatible with this driver
FS-x2010 Yes, No
FS-x2011 Yes, No
FS-x40 Yes, No

 

Connection Information

Connection type: EIA232 or EIA485 (Two wire, Half-Duplex)
Baud Rates: Standard Baud Rates up to 19200 (SK Device Limitation)
Data Bits: 8
Stop Bits: 1
Parity: None
Handshaking None

 

Proprietary Physical Interfaces Supported

Fieldserver Model Adapter Model # Vendor Physical Medium

 

Devices tested

Device Tested (FACTORY, SITE)
TLS-350 SITE

 

Connection configurations

 

Connection Notes

 

Communications functions

 

Supported functions at a glance:

 

Data Types Supported

FieldServer Data Type Description (or Device Data Type)
Analog Input
Digital Input
Analog Register
Digital Register
Analog Output
Digital Output

 

Read Operations supported

FieldServer as a Client FieldServer as a Server
Read Analog Status: Provide Analog Status:
Read Binary Status: Provide Binary Status:
Write Analog Setpoints: Accept Analog Setpoints:
Write Binary Commands: Accept Binary Commands:

 

Write (Control) Operations supported

FieldServer as a Client FieldServer as a Server
Read Analog Status: Provide Analog Status:
Read Binary Status: Provide Binary Status:
Write Analog Setpoints: Accept Analog Setpoints:
Write Binary Commands: Accept Binary Commands:


Unsupported Functions and Data Types

Function Reason
Programming messages FieldServer is a data transfer device, and as such, programming messages are not required

 

Functions Described

Unsupported Devices or Protocol Options

Device Details

 

Revision History

Date Driver Version Document Revision Resp
Comment
9/15/03 1.00 0 MF Created DFS
1/21/04 1.00 0 JD Releasing

 