Chipkin.com

Bacnet-Data-Conversion

Up one level

 

Data / Protocol Converters

  • Convert BACnet Data to over 110 other protocols using FieldServers
  • We sell, support, configure and develop custom drivers for FieldServer
  • Convert to/from Lonworks, Metasys N2 Open by JCI, Modbus, Rockwell, GE, Omron, HVAC, UPS, Cummins, Kohler, Power Meters, ION, PLCS, Many Fire Panels such as Simplex, Notifier, Siemens …. And many more
  • We can be a client, server and both client and server.

 

Free Explorer and Guide

 

When you purchase a gateway from CAS which includes a BACnet driver then we include a full license to the CAS BACnet Explorer. You can use the explorer to test / prove / document the BACnet interface. Some limitations apply to this offer and it is a limited time offer. Read more about the CAS BACnet Explorer.

 

You can purchase this guide for $20 from amazon.com or download the BACnet for Field Technicians for free.

 

Flavors of Bacnet

 

FieldServer’s support,

BACnet  IP,

MSTP,

802.3,

Arcnet

 

Convert

 

We have module solutions which allow integration directly into Bacnet products as well as the stand alone solutions shown bottom right.

 

Range of Conversion Solutions

 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

 

    FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
    FS25 Series
    2x RS232/485 1x Ethernet
    FS30 Series
    2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etc
    Hot Standby Support
    FS40 Series
    10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
    Hot Standby Support
    SlotServer
    1x RS232/485
    1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

    Lonworks and Fieldbus are options not proviced on base models.

 

Find your protocol

 

We have a huge list of protocols.

 

Block Diagram

 

Using a gateway you can integrate  non-bacnet devices into your system such a fire alarm panels, lighting systems, PLCs etc.

 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

 

 

 

S4 Group Solutions for Metasys N2 by JCI

 

S4 Open: BACnet-N2 Router

 

Typical Applications would be to bring data from the Metasys® N2 by JCI network into BACnet-based enterprise applications, energy management applications, or adding best-of-breed BACnet-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy Metasys® by JCI installations.

 

- S4 Open: BACnet-N2 Router Product Capabilities

 

Chipkin Automation and Bacnet

 

Chipkin Automation Systems has attended the BACnet plugfest in 2009, 2007 and 2006 to test its Bacnet Software and tools.

 

Data Sheets and Manuals

 

- Manual - FieldServer Driver - Serial - FS-8700-07 - BACnet Arcnet

- Manual - FieldServer Driver - Serial - FS-8700-73 - BACnet MSTP

- Manual - FieldServer Driver - Serial - FS-8704-02 - Bacnet Ethernet

- Data sheet - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP

- Manual - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP

- Data Sheet - FieldServer Driver - Serial - FS-8704-06 - BACnet IP

- Manual - FieldServer Driver - Serial - FS-8704-06 - BACnet IP

Data Sheet - CAS 2500-04 BACnetIP Data Client

Data Sheet - CAS 2500-04-UL BACnetIP Data Client

- Data Sheet - CAS 2500-05 BACnetEth Data Client

- Data Sheet - CAS 2500-05-UL BACnetEth Data Client

- Data Sheet - CAS 2500-06 BACnet MSTP Data Clien

- Data Sheet - CAS 2500-06-UL BACnet MSTP Data Client

 

More Data Sheets...

 

Need Help

 

Bacnet Web Site: www.bacnet.org

Need more info ? Call or email us.

 

Metasys® as used in this document is a trademark of Johnson Controls, Inc.