BACnet and Modbus Gateways
Up one levelBlock Diagram
Using a gateway you can integrate non-bacnet devices into your system such a fire alarm panels, lighting systems, PLCs etc.
FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

Flavors of Bacnet and Modbus
FieldServer’s support: BACnet IP, MSTP, 802.3, Arcnet, Modbus RTU, Modbus ASCII, Modbus+, Modbus/TCP. A single gateway can support many protocols.
Free Explorer and Guide
When you purchase a gateway from CAS which includes a BACnet driver then we include a full license to the CAS BACnet Explorer. You can use the explorer to test / prove / document the BACnet interface. Some limitations apply to this offer and it is a limited time offer. Read more about the CAS BACnet Explorer. You can purchase this guide for $20 from amazon.com or download the BACnet For Field Technicians for free.
Range of Conversion Solutions
Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.
| FS20 Series | 1x RS232/485 | 1x Ethernet | 1x Lonworks | ||
| FS25 Series |
2x RS232/485 | 1x Ethernet |
|||
| FS30 Series |
2x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support:eg Profibus, DeviceNet etc Hot Standby Support |
|
| FS40 Series |
10x RS232 and 2x RS485 | 2x Ethernet | 1x Lonworks | FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc Hot Standby Support |
|
| SlotServer |
1x RS232/485 |
1x Ethernet | 1x Lonworks | For Rockwell ControlLogix 5600 |
Lonworks and Fieldbus are options not proviced on base models.

Chipkin Automation and Bacnet
Chipkin Automation Systems has attended the BACnet plugfest in 2009, 2007 and 2006 to test its Bacnet Software and tools.
Data Sheets and Manuals
- Manual - FieldServer Driver - Serial - FS-8700-07 - BACnet Arcnet
- Manual - FieldServer Driver - Serial - FS-8700-73 - BACnet MSTP
- Manual - FieldServer Driver - Serial - FS-8704-02 - Bacnet Ethernet
- Data sheet - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP
- Manual - FieldServer Driver - Serial - FS-8700-16 - Bacnet PTP
- Data Sheet - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
- Manual - FieldServer Driver - Serial - FS-8704-06 - BACnet IP
- Data Sheet - FieldServer Driver - Serial - FS-8700-08 - Modbus ASCII
- Data Sheet - Serial - FS-8700-15 - Modbus Daniels
- Manual - Serial - FS-8700-15 - Modbus Daniels
- Data Sheet FieldServer Driver - Serial - FS-8700-33 - Modbus Omniflow
- Manual - FieldServer Driver - Serial - FS-8700-33 - Modbus Omniflow
- Data Sheet - FieldServer Driver - Fieldbus - FS-8700-02 - Modbus Plus
- Manual FieldServer Driver - Fieldbus - FS-8700-02 - Modbus Plus
- Data Sheet - FieldServer Driver - Serial - FS-8700-01 - Modbus RTU
- Manual - FieldServer Driver - Serial - FS-8700-01 - Modbus RTU
- Data Sheet - FieldServer Driver - Ethernet - FS-8704-03 - Modbus TCP
- Manual - FieldServer Driver - Ethernet - FS-8704-03 - Modbus TCP
- Data Sheet - FieldServer Driver - Serial - FS-8700-32 - Modbus Tek-Air
- Manual - FieldServer Driver - Serial - FS-8700-32 - Modbus Tek-Air
Find your protocol
We have a huge list of protocols.