<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chipkin Automation Systems - Articles &#187; FieldServer</title>
	<atom:link href="http://www.chipkin.com/articles/category/fieldserver/feed" rel="self" type="application/rss+xml" />
	<link>http://www.chipkin.com/articles</link>
	<description>Resources and News for industrial automation</description>
	<lastBuildDate>Tue, 07 Feb 2012 14:30:53 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Downloading Configuration and Firmware using RUInet</title>
		<link>http://www.chipkin.com/articles/downloading-configuration-and-firmware-using-ruinet</link>
		<comments>http://www.chipkin.com/articles/downloading-configuration-and-firmware-using-ruinet#comments</comments>
		<pubDate>Wed, 14 Dec 2011 17:00:38 +0000</pubDate>
		<dc:creator>llucica</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Utilities and tools]]></category>
		<category><![CDATA[RUI]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=895</guid>
		<description><![CDATA[The following is a set of instructions to Download the configuration file and firmware to a FieldServer using the RUInet utility. &#160; Downloading the Configuration File &#160; 1)      If you do not have RUInet installed yet then Download and Install the FieldServer Utilities. http://www.fieldserver.com/techsupport/utility/utility.php Download install.zip Install. 2)      The config file config.csv must be placed [...]]]></description>
			<content:encoded><![CDATA[<p>The following is a set of instructions to Download the configuration file and firmware to a FieldServer using the RUInet utility.</p>
<p>&nbsp;</p>
<p><strong>Downloading the Configuration File</strong></p>
<p>&nbsp;</p>
<p>1)      If you do not have RUInet installed yet then Download and Install the FieldServer Utilities.</p>
<ol>
<li><a href="http://www.fieldserver.com/techsupport/utility/utility.php">http://www.fieldserver.com/techsupport/utility/utility.php</a></li>
<li>Download install.zip</li>
<li>Install.</li>
</ol>
<p>2)      The config file config.csv must be placed in this folder, see Figure 1.</p>
<p>c:\FieldServer Technologies\FieldServer Utilities\Config</p>
<p>Put the config.csv file here</p>
<p><a href="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI-Config1.jpg"><img class="alignnone size-full wp-image-897" title="RUI Config" src="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI-Config1.jpg" alt="" width="934" height="461" /></a></p>
<p>3)      Connect a cable to your computer and start RUInet (Remote User Interface)</p>
<p>4)      From the main menu, <strong>Type D</strong> for download – you will be presented with the following page:</p>
<p><a href="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI2.jpg"><img class="alignnone size-full wp-image-898" title="RUI2" src="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI2.jpg" alt="" width="675" height="354" /></a></p>
<p>&nbsp;</p>
<p>5)      From the download screen, <strong>Type D</strong> to start the download of the config.csv file.  You will see a byte counter as the download proceeds.</p>
<p>6)      When the download is complete, push any key, then return to the main menu using ESC.</p>
<p><strong>Note: </strong>You need to restart the FieldServer to give effect to the new config, but before restarting, you can download the firmware as well.</p>
<p>&nbsp;</p>
<p><strong>Downloading new Firmware</strong></p>
<p>&nbsp;</p>
<p>1)      If you do not have RUInet installed yet then Download and Install the FieldServer Utilities.</p>
<ol>
<li><a href="http://www.fieldserver.com/techsupport/utility/utility.php">http://www.fieldserver.com/techsupport/utility/utility.php</a></li>
<li>Download install.zip</li>
<li>Install.</li>
</ol>
<p>&nbsp;</p>
<p>2)      The config file config.csv must be placed in this folder, see Figure 1.</p>
<p>c:\FieldServer Technologies\FieldServer Utilities\Config</p>
<p>File Name=fserver.img for FS20 and FS40,</p>
<p>File Name=nlx30 for FS30</p>
<p>File Name=nlx25.bin for FS25</p>
<p>File Name=nlpn.bin for CAS25</p>
<p>File Name = nlqs2.bin</p>
<p>&nbsp;</p>
<p><a href="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI3.jpg"><img class="alignnone size-full wp-image-899" title="RUI3" src="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI3.jpg" alt="" width="934" height="426" /></a></p>
<p>&nbsp;</p>
<p>3)      Connect a cable to your computer and start RUInet (Remote User Interface)</p>
<p>4)      From the main menu, <strong>Type D</strong> for download – you will be presented with the following page:</p>
<p><a href="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI4.jpg"><img class="alignnone size-full wp-image-900" title="RUI4" src="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI4.jpg" alt="" width="675" height="354" /></a></p>
<p>&nbsp;</p>
<p>5)      <strong>Push the ‘F’ key</strong> to tell the fieldserver you wish to download firmware.</p>
<p>6)      Type D to start the download.  You will see a byte counter as the download proceeds</p>
<p>7)      When the download is complete, push any key, then return to the main menu using ESC</p>
<p><strong>Note: </strong>You need to restart the FieldServer to give effect to the new firmware.</p>
<p>&nbsp;</p>
<p><strong>Restarting the Fieldserver</strong></p>
<p>&nbsp;</p>
<p>1)      In RUInet you will see the main menu as displayed below:</p>
<p><a href="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI5.jpg"><img class="alignnone size-full wp-image-901" title="RUI5" src="http://www.chipkin.com/articles/wp-content/uploads/2011/12/RUI5.jpg" alt="" width="677" height="353" /></a></p>
<p align="center">
<p>2)      From this menu, Press ‘Shift-1’ (or ‘!’) to Restart the FieldServer</p>
<p>3)      Wait for the FieldServer to reboot completely.  You should see the menu screen again when it is complete.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/downloading-configuration-and-firmware-using-ruinet/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Unpacking Bits from a 16bit Register in a FieldServer Configuration</title>
		<link>http://www.chipkin.com/articles/unpacking-bits-from-a-16bit-register-in-a-fieldserver-configuration</link>
		<comments>http://www.chipkin.com/articles/unpacking-bits-from-a-16bit-register-in-a-fieldserver-configuration#comments</comments>
		<pubDate>Fri, 14 Aug 2009 18:15:18 +0000</pubDate>
		<dc:creator>pchipkin</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[16]]></category>
		<category><![CDATA[16-bit]]></category>
		<category><![CDATA[16bit]]></category>
		<category><![CDATA[array]]></category>
		<category><![CDATA[bit]]></category>
		<category><![CDATA[configuration]]></category>
		<category><![CDATA[register]]></category>
		<category><![CDATA[unpack]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=437</guid>
		<description><![CDATA[Introduction What happens if you want to serve some/all of the bits that form a 16 bit register. ie. Your client reads a 16bit register but you want to serve those bits as separate binary objects. Here is an example Lets say the client reads 40001 data into DA_REG[0] (Data Array = DA_REG Offset=0) The [...]]]></description>
			<content:encoded><![CDATA[<h4 style="border-bottom: 1px solid #8cacbb;">Introduction</h4>
<p>What happens if you want to serve some/all of the bits that form a 16 bit register. ie. Your client reads a 16bit register but you want to serve those bits as separate binary objects.</p>
<h4 style="border-bottom: 1px solid #8cacbb;">Here is an example</h4>
<div>Lets say the client reads 40001 data into DA_REG[0] (Data Array = DA_REG Offset=0)</p>
<p>The 1<sup>st</sup> Move copies 1x 16 bit number from DA_REG[0] to DA_PACKED[0].</p>
<p>DA_Packed’s offsets can be interpreted in two ways:</p></div>
<ul>
<li>A series of 16 bit numbers</li>
<li>A series of bits</li>
</ul>
<p>It depends on what kind of operation access the Data Array. If it’s a 16 bit or analog number type operation then it addesses 16 bit numbers. If the operation is a bit operation like for a binary data point then the operation addresses each bit.</p>
<p>Therefore DA_PACKED[0] is ambiguous.</p>
<p>If you connected a server Map Descriptor to that point and the type is an Analog In/output then it means the 16bit number found at DA_PACKED[0].</p>
<p>If you connected a server Map Descriptor to that point and the type is an Binary In/output then it means the bit number found at DA_PACKED[0] and DA_PACKED[15] is the 16<sup>th</sup> bit. DA_PACKED[16] is the 1<sup>st</sup> bit of the next 16 bit number&#8230;</p>
<p>If that seems to complicated then add one more move:</p>
<p>Data_Arrays</p>
<table border="0">
<tbody>
<tr>
<td>Move_Only</td>
<td>DA_PACKED</td>
<td>0</td>
<td>DA_BIT</td>
<td>0</td>
<td>16</td>
</tr>
</tbody>
</table>
<p>This move moves the 16 bits for DA_PACKED[0] to 16 separate bits with unambiguous offsets and you can use those in the server map descriptors.</p>
<h4 style="border-bottom: 1px solid #8cacbb;">Heads Up</h4>
<div>Some Modbus server devices number the bits in reverse order. You can only be sure when you test.</div>
<div>
Data_Arrays</div>
<table border="0" cellpadding="2">
<tbody>
<tr>
<td>Data_Array_Name</td>
<td>Data_Format</td>
<td>Data_Array_Length</td>
</tr>
<tr>
<td>DA_REG</td>
<td>UINT16</td>
<td>20</td>
</tr>
<tr>
<td>DA_PACKED</td>
<td>Packed_Bit</td>
<td>100</td>
</tr>
<tr>
<td>DA_BIT</td>
<td>BIT</td>
<td>1200</td>
</tr>
</tbody>
</table>
<p>Preloads</p>
<table border="0" cellpadding="2">
<tbody>
<tr>
<td>Data_Array_Name</td>
<td>Preload_Data_Index</td>
<td>Preload_Data_Value</td>
</tr>
<tr>
<td>DA_REG</td>
<td>0</td>
<td>33</td>
</tr>
</tbody>
</table>
<p>Moves</p>
<table border="0" cellpadding="2">
<tbody>
<tr>
<td>Function</td>
<td>Source_Data_Array</td>
<td>Source_Offset</td>
<td>Target_Data_Array</td>
<td>Target_Offset</td>
<td>Length</td>
</tr>
<tr>
<td>Move_Only</td>
<td>DA_REG</td>
<td>0</td>
<td>DA_PACKED</td>
<td>0</td>
<td>1</td>
</tr>
<tr>
<td>Move_Only</td>
<td>DA_PACKED</td>
<td>0</td>
<td>DA_BIT</td>
<td>0</td>
<td>16</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/unpacking-bits-from-a-16bit-register-in-a-fieldserver-configuration/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Node Offline Responses</title>
		<link>http://www.chipkin.com/articles/node-offline-responses</link>
		<comments>http://www.chipkin.com/articles/node-offline-responses#comments</comments>
		<pubDate>Mon, 01 Jun 2009 12:52:36 +0000</pubDate>
		<dc:creator>skapoor</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Client]]></category>
		<category><![CDATA[data]]></category>
		<category><![CDATA[Map Descriptors]]></category>
		<category><![CDATA[Nodes]]></category>
		<category><![CDATA[Offline]]></category>
		<category><![CDATA[Online]]></category>
		<category><![CDATA[Response]]></category>
		<category><![CDATA[server]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=390</guid>
		<description><![CDATA[When a Client Node on the FieldServer goes offline the corresponding data objects on the FieldServer are also marked offline. If a client polls a virtual FieldServer node for this particular data, an offline response will be returned by the FieldServer. If the client then requests the FieldServer to identify itself, a valid response will [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span>When a <strong>Client Node</strong> on the <strong>FieldServer</strong> goes offline the corresponding data objects on the FieldServer are also marked offline. If a client polls a virtual FieldServer node for this particular data, an offline response will be returned by the FieldServer. If the client then requests the FieldServer to identify itself, a valid response will be provided in spite of the data being offline. This results in status toggle, with the Server side Client receiving no replies to data requests and marking the Node offline and then again marking the node online after a successful identification poll, then again receiving no replies to data requests and marking the node offline and so on.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span>The <strong>Server Node</strong> must therefore be capable of deciding the nature of its response based on the status of relevant Client Nodes. This can be accomplished using responsible Map Descriptors (RDBC, WRBX, and WRBC). In case no acknowledgement of these functions is received, the device is identified as offline and a flag is placed at the data array offset. The virtual FieldServer can be configured using the <span>Offline_Method </span>option to respond to identification requests in one of the following ways:</span></p>
<ol>
<li><! [if !supportLists] ><strong><span>Ignore_Clients/No Setting </span></strong><span><strong>(default)</strong> – The kernel ignores the status of Client side Nodes and uses only the online/offline status of relevant data objects to decide on the type of response.</span></li>
<li><! [if !supportLists] ><span><strong>Any_Offline</strong> </span><span>– If any relevant Client Node is offline the Server Node will respond with a node offline message as defined by the Server protocol. This option is available for selected drivers only.</span></li>
<li><! [if !supportLists] ><span><strong>All_Offline</strong> </span><span>– If <span>all<em> </em></span>relevant Client Nodes are offline the Server Node will respond with a node offline message as defined by the Server protocol<span>. </span>This option is available for selected drivers only.</span></li>
<li><! [if !supportLists] ><span><strong>Always_Respond</strong> </span><span>– A response with data currently in the FieldServer is <span>always </span>sent, without considering the online/offline status of the relevant Client Nodes. This option is available for all drivers.</span></li>
</ol>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span>Offline Server Nodes are treated differently by different protocols. Some protocols will have an explicit offline response, while others will simply not respond.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;" mce_style="margin-bottom: 0.0001pt; line-height: normal;"><span>If configured, the node offline response will take priority over the data offline response.</span><--></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/node-offline-responses/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Timing Parameters</title>
		<link>http://www.chipkin.com/articles/timing-parameters</link>
		<comments>http://www.chipkin.com/articles/timing-parameters#comments</comments>
		<pubDate>Mon, 01 Jun 2009 12:46:13 +0000</pubDate>
		<dc:creator>skapoor</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Connections]]></category>
		<category><![CDATA[Delay]]></category>
		<category><![CDATA[Interval]]></category>
		<category><![CDATA[Map Descriptors]]></category>
		<category><![CDATA[Nodes]]></category>
		<category><![CDATA[Poll delay]]></category>
		<category><![CDATA[Poll request]]></category>
		<category><![CDATA[Probation]]></category>
		<category><![CDATA[Recovery]]></category>
		<category><![CDATA[Retry]]></category>
		<category><![CDATA[Timeout]]></category>
		<category><![CDATA[Timing Parameter]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=383</guid>
		<description><![CDATA[Normally a FieldServer sends a poll request to a Server device and that device gives a response back to the FieldServer. Following are the timing parameters considered important in the fieldserver’s operation:   Scan_interval: It is the amount of time between successive poll requests. Its default value is 2 seconds and it belongs to Map [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span>Normally a <strong>FieldServer</strong> sends a <strong>poll request</strong> to a Server device and that device gives a response back to the FieldServer. </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span>Following are the <strong>timing parameters</strong> considered important in the fieldserver’s operation:</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Scan_interval</span></strong><strong><span>:</span></strong><span> It is the amount of time between successive poll requests. Its default value is 2 seconds and it belongs to Map descriptors, nodes and connections.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Poll_delay:</span></strong><span> </span><span><span> </span>It is the time between receiving a response from a server device and the next poll request. Its default value is 0.05 seconds and it belongs to Connections only.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Timeout:</span></strong><span> If the FieldServer sends a poll request, and the Server device does not send a response, it is considered a timeout. The time for which the FieldServer waits before declaring a timeout can be adjusted by the <span>timeout </span>parameter. Its default value is 2 seconds and it belongs to Map descriptors, nodes and connections.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>ic_timeout:</span></strong><span> <span> </span>This parameter monitors the time between characters in a response. If the time exceeds the ic_timeout, the response is discarded and is considered a timeout. Its default value is 0.5 seconds and it belongs to Map descriptors, nodes and connections.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Retries:</span></strong><span> If a timeout occurs, then the FieldServer will retry the poll request a few more times. Number of times tried is specified by the <span>retries </span>parameter. Its default value is 3 times and belongs to nodes only.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><span> </span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Retry_interval</span></strong><strong><span>:</span></strong><span> The interval between <span>retries </span>is specified by the <span>retry_interval</span>. The Fieldserver will send poll requests at the end of each <span>retry_interval. </span>Once the specified numbers of <span>retries </span>have been sent, the<span> </span>FieldServer will mark the node offline. Its default value is 10 seconds and belongs to nodes only.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"> </p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Recovery_interval:</span></strong><span> </span><span>Once a node has been marked offline, it will wait for a period specified by <span>recovery_interval </span>before sending another poll request. Its default value is 30 seconds and it belongs to nodes only.</span></p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"> </p>
<p class="MsoNormal" style="margin-bottom: 0.0001pt; line-height: normal;"><strong><span>Probation_delay</span></strong><strong><span>:</span></strong><span> Once the communications have been re-established, the FieldServer will wait for a period called <span>probation_delay</span>, before marking the node as online. Its default value is 1 minute and it belongs to nodes only.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/timing-parameters/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FieldServer’s Web Server</title>
		<link>http://www.chipkin.com/articles/fieldserver%e2%80%99s-web-server</link>
		<comments>http://www.chipkin.com/articles/fieldserver%e2%80%99s-web-server#comments</comments>
		<pubDate>Mon, 27 Apr 2009 23:07:03 +0000</pubDate>
		<dc:creator>cpascu</dc:creator>
				<category><![CDATA[BACnet]]></category>
		<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[browser]]></category>
		<category><![CDATA[devices]]></category>
		<category><![CDATA[server]]></category>
		<category><![CDATA[Web]]></category>
		<category><![CDATA[webserver]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=293</guid>
		<description><![CDATA[In a nutshell: The FieldServer reads data from field devices. This data can be used to animate web pages that can be served by the FieldServer. Using a browser, a customer or user can monitor data from field devices and also control them. A little more detail: The FieldServer Web Server allows you to display [...]]]></description>
			<content:encoded><![CDATA[<p>In a nutshell:</p>
<ul>
<li>The FieldServer reads data from field devices.</li>
<li>This data can be used to animate web pages that can be served by the FieldServer.</li>
<li>Using a browser, a customer or user can monitor data from field devices and also control them.</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-295  aligncenter" title="july08art2pic1" src="http://www.chipkin.com/articles/wp-content/uploads/2009/04/july08art2pic1-300x250.jpg" alt="july08art2pic1" width="300" height="250" /></p>
<p><strong>A little more detail:</strong></p>
<p style="padding-left: 25px;">The FieldServer Web Server allows you to display and change data in a FieldServer. The FieldServer’s data is obtained by communication with remote devices such as gas Detectors, Lighting Controllers and many more.</p>
<p>The web server is a front end HMI (human machine interface) that can serve screens and data to any web browser such as Internet Explorer. Amongst other things, it allows your users to view and change values on your devices with out having to install any special software or be anywhere near the site.</p>
<p>Since the system is built in to a webpage, most of your users should already have the required skills to operate the system (click the link, push a button, flip a switch), a lower learning curve and less training. So simple that just about anyone can operate the system.</p>
<p>Your users can connect and change values on your devices from anywhere that has an internet connection and a web browser. Imagine sitting down in the comfort of your own home, and browsing to your site, viewing the status and making any changes that are needed, then rolling over and going back to sleep, with having to set one foot on the site.</p>
<p>The values on your device can be displayed in a number of ways from simple text and progress bars to animated images and sliders, its up to you how you want to display your data and the system is flexible to do just about anything you can think of, while remaining simple enough for anyone to use.</p>
<p>The system uses a simple template tag system to display and change the data on your devices; these tags can be inserted in to any html document and placed on the FieldServer. The server will then will run thou and strip out these tags and replace them with the data from your device. Its much simpler then it sounds, put this tag where you want to show your data. The template tags are built with web designers in mind, there simple to use and simple to debug.</p>
<p> </p>
<p><strong>How it all works:</strong></p>
<p style="padding-left: 25px;">This system works by creating a mini web server on our FieldServer that the users can browse to. When a user browses a webpage, the FieldServer searched the html document for special template tags, if the FieldServer finds these special template tags in the html document, it replaces them with data from your device. When you push a button on one of these web pages, the value is sent from your webpage to the FieldServer, to your device.</p>
<p style="text-align: center;"><img class="size-medium wp-image-296  aligncenter" title="july08art2pic2" src="http://www.chipkin.com/articles/wp-content/uploads/2009/04/july08art2pic2-300x218.jpg" alt="july08art2pic2" width="300" height="218" /></p>
<p style="padding-left: 25px;"><em>Step 1:</em> FieldServer is configured to read data from field devices using RS232/ RS485/ Ethernet, Controlnet, DeviceNet, DH+, Modbus+ and any combination of drivers from the extensive protocol library. Over 100 protocols are available.</p>
<p><em>Step 2:</em> A browser surfs the FieldServer. Pages served are just like any other html pages except that they can include animations based on the real time data obtained from the field devices. The pages can also contain elements to change the data in the FieldServer. These changes then get sent back down to the field devices, if this is what you require.</p>
<p><em>Step 3:</em> Data read from the field devices can also be served to other field devices using another protocol. It depends on your requirements.</p>
<p> </p>
<h3>Examples</h3>
<p> <br />
These are some of the examples you can produce with this system, the system is only limited by your imagination.<br />
 </p>
<p><strong>Simple Example </strong></p>
<p>In this simple example we are only using the very basics of the template system, (display text and action buttons) but you can instantly see the power of this system, its easy to read, it’s easy to operate, it provides all the information that the user needs about the building.</p>
<p style="text-align: center;"><img class="size-medium wp-image-297  aligncenter" title="july08art2pic3" src="http://www.chipkin.com/articles/wp-content/uploads/2009/04/july08art2pic3-300x152.jpg" alt="july08art2pic3" width="300" height="152" /></p>
<p><strong>Sleek and Pretty Example</strong></p>
<p>In this example we put an information tag on an image of the factory; the loading doc has two tags associated with it, Lights and AC. You can see that the lights are on and the AC is off, the boarder is flashing red indicating a panic, the user then could click on this tag and get a screen similar to the one above where they can get more information and acknowledge the alarm.</p>
<p style="text-align: center;"><img class="size-medium wp-image-298  aligncenter" title="july08art2pic4" src="http://www.chipkin.com/articles/wp-content/uploads/2009/04/july08art2pic4-300x186.jpg" alt="july08art2pic4" width="300" height="186" /></p>
<p><strong>Mirror example</strong></p>
<p style="text-align: center;">In this example we copied the front display of the real device, anyone that has used the device before can quickly and easily navigate this interface.<br />
<img class="size-medium wp-image-299  aligncenter" title="july08art2pic5" src="http://www.chipkin.com/articles/wp-content/uploads/2009/04/july08art2pic5-300x163.jpg" alt="july08art2pic5" width="300" height="163" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/fieldserver%e2%80%99s-web-server/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FieldServer Gateway (Dual Serial)</title>
		<link>http://www.chipkin.com/articles/fieldserver-gateway-dual-serial</link>
		<comments>http://www.chipkin.com/articles/fieldserver-gateway-dual-serial#comments</comments>
		<pubDate>Mon, 27 Apr 2009 22:52:45 +0000</pubDate>
		<dc:creator>cpascu</dc:creator>
				<category><![CDATA[BACnet]]></category>
		<category><![CDATA[BACnet MSTP]]></category>
		<category><![CDATA[Ethernet]]></category>
		<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[10/100BaseT]]></category>
		<category><![CDATA[B2510]]></category>
		<category><![CDATA[dual]]></category>
		<category><![CDATA[FS-B2510]]></category>
		<category><![CDATA[FS-X30]]></category>
		<category><![CDATA[gateway]]></category>
		<category><![CDATA[serial]]></category>
		<category><![CDATA[X30]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=290</guid>
		<description><![CDATA[Dual Serial – Ethernet FS-B2510 The FS-B2510 Dual Serial-Ethernet gateway provides a wealth of features to enable data transfer between different devices and networks utilizing serial and Ethernet protocols. The extensive library of FieldServer drivers provides easy interoperability with devices and networks used in building automation, HVAC, fire and process control industries. The FS-B2510 is [...]]]></description>
			<content:encoded><![CDATA[<table border="0">
<tbody>
<tr>
<td><img src="/files/newsletters/img/bridge_sm.jpg" alt="" align="right" /><strong>Dual Serial – Ethernet</p>
<p>FS-B2510</strong></p>
<p>The FS-B2510 Dual Serial-Ethernet gateway provides a wealth of features to enable data transfer between different devices and networks utilizing serial and Ethernet protocols. The extensive library of FieldServer drivers provides easy interoperability with devices and networks used in building automation, HVAC, fire and process control industries. The FS-B2510 is particular cost effective in the integration of two devices/systems utilizing serial protocols such as a fire alarm control panel to BACnet MSTP.</td>
</tr>
<tr>
<td>The FS-B2510 is one of the FS-X30 Series FieldServers designed to meet the needs of system integrators in designing a complete interoperable system. The FS-B25 Series brings together the powerful FieldServer driver library with state-of-the-art gateway design. This FieldServer includes twi serial connections (RS-232 or RS-485, software selectable) and one 10/100BaseT Ethernet ports. The multiport design allows for serial-to-serial interfaces or interface from mulitple serial products to an Ethernet or LonWorks network. The Ethernet port enables the integrator to connect a PC to download configuration changes without disturbing the system connections and without the additional cost of an external hub.</p>
<p><strong><span style="font-size: x-small;">CAS sell, support, install, configure and develop custom drivers for FieldServers. With every FieldServer purchased from CAS that includes a BACnet protocol we provide a free license to the CAS BACnet Explorer which can be used to test / prove the BACnet interface is working.</span></strong></td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/fieldserver-gateway-dual-serial/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Four (4) Jumpers are required to connect a FS2510 to a 2-wire RS485 System</title>
		<link>http://www.chipkin.com/articles/four-4-jumpers-are-required-to-connect-a-fs2510-to-a-2-wire-ts485-system</link>
		<comments>http://www.chipkin.com/articles/four-4-jumpers-are-required-to-connect-a-fs2510-to-a-2-wire-ts485-system#comments</comments>
		<pubDate>Mon, 10 Nov 2008 23:59:21 +0000</pubDate>
		<dc:creator>cpascu</dc:creator>
				<category><![CDATA[Cables]]></category>
		<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[RS485]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[FS2510]]></category>
		<category><![CDATA[LED]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=197</guid>
		<description><![CDATA[In early versions of the FS2510 the serial LED does not flicker even when there is normal RS485 activity. Devices with firmware version 5.12k are known to require a firmware upgrade. Contact Tech support for help.]]></description>
			<content:encoded><![CDATA[<p>In early versions of the FS2510 the serial LED does not flicker even when<br />
there is normal RS485 activity.</p>
<p>Devices with firmware version 5.12k are known to require a firmware upgrade.<br />
Contact Tech support for help.</p>
<p><center> <a href='http://www.chipkin.com/articles/wp-content/uploads/2008/11/image002.png'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/11/image002-263x300.png" alt="" title="image002" width="263" height="300" class="alignnone size-medium wp-image-199" /></a> </center></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/four-4-jumpers-are-required-to-connect-a-fs2510-to-a-2-wire-ts485-system/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Multiple Clients of a Modbus slave</title>
		<link>http://www.chipkin.com/articles/multiple-clients-of-a-modbus-slave</link>
		<comments>http://www.chipkin.com/articles/multiple-clients-of-a-modbus-slave#comments</comments>
		<pubDate>Wed, 22 Oct 2008 19:21:11 +0000</pubDate>
		<dc:creator>cpascu</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Modbus]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[clients]]></category>
		<category><![CDATA[multiple]]></category>
		<category><![CDATA[slave]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=188</guid>
		<description><![CDATA[We are frequenty asked how you deal with a situation where you have more than one client for a slave(s). The Modbus spec does not support this but we have a solution. The essence of the solution if to use a multi-port FieldServer. Connect each client to its own port and the slave(s) to thier [...]]]></description>
			<content:encoded><![CDATA[<p>We are frequenty asked how you deal with a situation where you have more than one client for a slave(s). The Modbus spec does not support this but we have a solution.</p>
<p>The essence of the solution if to use a multi-port FieldServer. Connect each client to its own port and the slave(s) to thier own ports. Each client will see a single virtual slave(s) on its network. This not only solves the problem but is extremely efficient. Of course the FieldServer needs to be correctly configured.</p>
<p>In a situation like this we exploit the FieldServer technology known as &#8216;Port Expansion&#8217;</p>
<p><strong>Figure 1: </strong>Normally it is not possible to connect two clients to the same slave. There are two primary reasons:<br />
1) If you are using RS232 then there can only be two devices on the cable segment.<br />
2) If you are using RS485 then the 2nd client will not know to proceess the poll from the 1st client. It will cause errors.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex12.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex12-300x132.jpg" alt="" title="pex12" width="300" height="132" class="alignnone size-medium wp-image-189" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 2:</strong> Using a FieldServer with an appropriate configuration solves this problem whether you are using RS232 otr RS485.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex21.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex21-300x132.jpg" alt="" title="pex21" width="300" height="132" class="alignnone size-medium wp-image-190" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 3:</strong> Each client is on its own port. Thus each client does not see poll messages from the other client. In this example client#1 sends a poll to the FieldServer. The is directed a specific slave address. When the poll arrives at the FieldServer, the FieldServer checks the address against its configuration. If there is no match then an exception response is sent. If there is a match the FieldServer determines the port that the matching slave is configured on. The poll message is then relayed to the slave port.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex31.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex31-300x132.jpg" alt="" title="pex31" width="300" height="132" class="alignnone size-medium wp-image-191" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 4:</strong> The slave responds. The FieldServer relays the response to client#1. The FieldServer also extracts the data from the response and stores in a temporary location (FieldServer calls that a cache block). The duration/expiry of the storage is configurable.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex42.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex42-300x145.jpg" alt="" title="pex42" width="300" height="145" class="alignnone size-medium wp-image-192" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 5:</strong> If any client requests the same data (client#1 or #2) and the data hasnt expired then the FieldServer responds with data from the temporary storage.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex51.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex51-300x145.jpg" alt="" title="pex51" width="300" height="145" class="alignnone size-medium wp-image-193" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 6:</strong> If any client requests different data or if the temporary data has expired then the match and relay process is repeated requesting the new data.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex61.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex61-300x132.jpg" alt="" title="pex61" width="300" height="132" class="alignnone size-medium wp-image-194" /></a><br />
<br /><small>Click to enlarge</small></center></p>
<p><strong>Figure 7:</strong> The slave responds, the response is relayed to the client doing the polling (Client#2 in this case) and the data is stored temporarily so that it is available to the other client.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex71.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/pex71-300x145.jpg" alt="" title="pex71" width="300" height="145" class="alignnone size-medium wp-image-195" /></a><br />
<br /><small>Click to enlarge</small></center></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/multiple-clients-of-a-modbus-slave/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Scaling / Bit Packing</title>
		<link>http://www.chipkin.com/articles/scaling-bit-packing</link>
		<comments>http://www.chipkin.com/articles/scaling-bit-packing#comments</comments>
		<pubDate>Tue, 21 Oct 2008 20:26:13 +0000</pubDate>
		<dc:creator>cpascu</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Modbus]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[bit packing]]></category>
		<category><![CDATA[fieldservers]]></category>
		<category><![CDATA[rtu]]></category>
		<category><![CDATA[scaling]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=186</guid>
		<description><![CDATA[FieldServers can scale data and manipulate values using some binary logic and arithmetic functions. Scaling can be applied to each block of Modbus Data read/served. Move to change type : Convert from any FIeldServer Data Type to any other. Move to pack/unpack bits and bytes: Its possible to address each bit in a 8,16 or [...]]]></description>
			<content:encoded><![CDATA[<p>FieldServers can scale data and manipulate values using some binary logic and arithmetic functions. Scaling can be applied to each block of Modbus Data read/served.</p>
<ul>
<li>Move to change type : Convert from any FIeldServer Data Type to any other. </li>
<li>Move to pack/unpack bits and bytes: Its possible to address each bit in a 8,16 or 32 bit data element by using the packed data types. </li>
<li>Move to change byte/word order: Handle the endianess of the remote system easily. </li>
<li>Convert to/from Float, MK10, IEE754, 32 bit, 16 bit, 8 bit numbers </li>
<li>Move conditionally: </li>
<li>Perform Arithmetic Operation: + &#8211; * div sqrt, sqr</li>
<li>Perform Binary Logic Operation: And, Or, Not, >, >= , <, <= </li>
</ul>
<p>Most functions can be configured to occur on a configurable period or on update of the data source.</p>
<p><center><a href='http://www.chipkin.com/articles/wp-content/uploads/2008/10/scalingarticlepic.jpg'><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/10/scalingarticlepic-242x300.jpg" alt="" title="scalingarticlepic" width="242" height="300" class="alignnone size-medium wp-image-187" /><br /> Click for larger view </a></center></p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/scaling-bit-packing/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Simplex 4100u FieldServer Configurations</title>
		<link>http://www.chipkin.com/articles/simplex-4100u-fieldserver-configurations</link>
		<comments>http://www.chipkin.com/articles/simplex-4100u-fieldserver-configurations#comments</comments>
		<pubDate>Fri, 28 Mar 2008 19:31:47 +0000</pubDate>
		<dc:creator>pchipkin</dc:creator>
				<category><![CDATA[FieldServer]]></category>
		<category><![CDATA[Simplex 4100]]></category>

		<guid isPermaLink="false">http://www.chipkin.com/articles/simplex-4100u-fieldserver-configurations</guid>
		<description><![CDATA[When simplex 4100U&#8217;s are networekd together the configuration of a FieldServer needs special considerations. Follow these steps 1. Use the correct input doc. It must say &#8216;HW Ref&#8217;. This is the only report that can be used. 2. Use the HW Ref column to work out which card-point-subPoints you need to capture in the configuration. You [...]]]></description>
			<content:encoded><![CDATA[<p>When simplex 4100U&#8217;s are networekd together the configuration of a FieldServer needs special considerations.</p>
<p>Follow these steps</p>
<p>1. Use the correct input doc. It must say &#8216;HW Ref&#8217;. This is the only report that can be used.</p>
<p><a title="Sim4100 Input Report" href="http://www.chipkin.com/articles/wp-content/uploads/2008/03/sim4100a2.GIF"><img src="http://www.chipkin.com/articles/wp-content/uploads/2008/03/sim4100a2.GIF" alt="Sim4100 Input Report" /></a></p>
<p>2. Use the HW Ref column to work out which card-point-subPoints you need to capture in the configuration.</p>
<p>You will need one Map Descriptor for each card. </p>
<p>3. Points from networked panels lose their original HW ref and get a new based on the network card.</p>
<p>For example if the network card is card 3 then all the points from the remote panels will come in as card=3.</p>
<p>The HW Ref will be 3-xxxxx</p>
<p>The trick is to convert the xxxxx to a point-SubPoint address so you can work out where the event will be stored in the data array.</p>
<p>4. Make a Map Descripto to cpature events from card 3.</p>
<p>Map_Descriptors<br />
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,<br />
Node_Name  ,sim4100_func ,sim4100_card ,sim4100_point ,sim4100_sub ,<br />
protocol ,length ,Card_03_Points ,DA_CARD3 ,0 ,passive  ,Simplex_01 ,<br />
xpoint ,3 ,0 ,256 ,sim4100 ,20000</p>
<p>There can only be one Map Desc for card 3.</p>
<p>Always set point to zero</p>
<p>Set SubPoint to 256 for networked points. (This means the driver expects 256 subpoints per point)</p>
<p>5.  Determine the Data Array Offset where a point&#8217;s event will be stored.</p>
<p>Convert the HW Ref to Point-SubPoint</p>
<p>For example:</p>
<p>Input Doc: 3-14126      3:M4-78-0        RIAM          RELAY           L2 BAK/CHE T2.035 CORR BY MEET RM B7.011</p>
<p>HW Ref=3-14126 so we know the card=3</p>
<p>temp=14126</p>
<p>temp2 = temp &#8211; 1</p>
<p>point = trunc(temp2/256)   trunc=truncated division. Rounds down.</p>
<p>subPoint = temp &#8211; point *256</p>
<p>Offset into Data Array = (point+1)*256+subPoint</p>
<p>Thus in this example: Offset=14381. When the point has an event, the data will be stored in DA_CARD3[14381].<br />
 <br />
 </p>
]]></content:encoded>
			<wfw:commentRss>http://www.chipkin.com/articles/simplex-4100u-fieldserver-configurations/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>