<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: BACnet BIBB&#8217;s TABLE &#8211; Bacnet Interoperability Building Blocks</title>
	<atom:link href="http://www.chipkin.com/articles/bacnet-bibbs-table-bacnet-interoperability-building-blocks/feed" rel="self" type="application/rss+xml" />
	<link>http://www.chipkin.com/articles/bacnet-bibbs-table-bacnet-interoperability-building-blocks</link>
	<description>Resources and News for industrial automation</description>
	<lastBuildDate>Mon, 16 Jan 2012 10:29:36 +0000</lastBuildDate>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
	<item>
		<title>By: prakash dsouza</title>
		<link>http://www.chipkin.com/articles/bacnet-bibbs-table-bacnet-interoperability-building-blocks/comment-page-1#comment-953</link>
		<dc:creator>prakash dsouza</dc:creator>
		<pubDate>Thu, 17 Dec 2009 12:01:42 +0000</pubDate>
		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=243#comment-953</guid>
		<description>Hi,

I am a 3rd party client connected to a field server fs-B40 device as a gateway for fire panel. We requested data to be sent to us as notification class. Client has done the following configuration in the device for alarm notificaiton to be sent to my software -- dev id = 1048577. My object scanner shows notification block list (obj id=100) showing recepient list device = 33554432. 

I am not able receive alarm as a notification. but i can read the alarms. Is there a problem with the below config.

prakash..

&lt;code&gt;
Connections,,,,,,,,,,,,,
Adapter ,Protocol  ,poll_delay,Connection_Type,IP_port,,,,,,,,,
N1      ,Bacnet_IP ,0,-,-,,,,,,,,,
N2,Bacnet_IP ,0,BBMD,47808,,,,,,,,,
,,,,,,,,,,,,,
//================================================================================,,,,,,,,,,,,,
//,,,,,,,,,,,,,
//    Server Side Nodes,,,,,,,,,,,,,
//,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Nodes,,,,,,,,,,,,,
Node_Name      ,Node_ID ,Protocol,,,,,,,,,,,
Virtual_BCU_12 ,12,Bacnet_IP,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Nodes,,,,,,,,,,,,,
Node_Name        ,Node_ID ,Protocol   ,Adapter , Timeout,,,,,,,,,
Alarm_Event_Node ,1048577,Bacnet_IP  ,N2,0.3,,,,,,,,,
,,,,,,,,,,,,,
Map_Descriptors,,,,,,,,,,,,,
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name   ,Data_Type ,Object_ID ,Length ,Ack_Required ,Event_Receiver_Name,,,,
BAC_NC_EST          ,DA_NC_EST       ,0,Server   ,Virtual_BCU_12 ,NC        ,100,1,Yes          ,Alarm_Event_Node,,,,
,,,,,,,,,,,,,
//================================================================================,,,,,,,,,,,,,
//,,,,,,,,,,,,,
//    Server Side Map Descriptors,,,,,,,,,,,,,
//,,,,,,,,,,,,,
,,,,,,,,,,,,,
//Map Descriptor for Event Notification,,,,,,,,,,,,,
Map_Descriptors,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Map_Descriptors,,,,,,,,,,,,,
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name ,Data_Type ,Object_ID ,Input_Alarm_State ,Notification_Class ,Active_Text ,Inactive_Text,,,
L1_SMK1,DA_Trb_01       ,0,Server   ,Virtual_BCU_12 ,BI        ,30000,1,BAC_NC_EST         ,Alarm       ,Normal,,,
L1_SMK2,DA_Trb_01       ,1,Server   ,Virtual_BCU_12 ,BI        ,30001,1,BAC_NC_EST         ,Alarm       ,Normal,,,
L1_SMK3,DA_Trb_01       ,2,Server   ,Virtual_BCU_12 ,BI,30002,1,BAC_NC_EST         ,Alarm       ,Normal,,,
L1_SMK4,DA_Trb_01       ,3,Server   ,Virtual_BCU_12 ,BI,30003,1,BAC_NC_EST         ,Alarm       ,Normal,,,
&lt;/code&gt;</description>
		<content:encoded><![CDATA[<p>Hi,</p>
<p>I am a 3rd party client connected to a field server fs-B40 device as a gateway for fire panel. We requested data to be sent to us as notification class. Client has done the following configuration in the device for alarm notificaiton to be sent to my software &#8212; dev id = 1048577. My object scanner shows notification block list (obj id=100) showing recepient list device = 33554432. </p>
<p>I am not able receive alarm as a notification. but i can read the alarms. Is there a problem with the below config.</p>
<p>prakash..</p>
<p><code><br />
Connections,,,,,,,,,,,,,<br />
Adapter ,Protocol  ,poll_delay,Connection_Type,IP_port,,,,,,,,,<br />
N1      ,Bacnet_IP ,0,-,-,,,,,,,,,<br />
N2,Bacnet_IP ,0,BBMD,47808,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
//================================================================================,,,,,,,,,,,,,<br />
//,,,,,,,,,,,,,<br />
//    Server Side Nodes,,,,,,,,,,,,,<br />
//,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
Nodes,,,,,,,,,,,,,<br />
Node_Name      ,Node_ID ,Protocol,,,,,,,,,,,<br />
Virtual_BCU_12 ,12,Bacnet_IP,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
Nodes,,,,,,,,,,,,,<br />
Node_Name        ,Node_ID ,Protocol   ,Adapter , Timeout,,,,,,,,,<br />
Alarm_Event_Node ,1048577,Bacnet_IP  ,N2,0.3,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
Map_Descriptors,,,,,,,,,,,,,<br />
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name   ,Data_Type ,Object_ID ,Length ,Ack_Required ,Event_Receiver_Name,,,,<br />
BAC_NC_EST          ,DA_NC_EST       ,0,Server   ,Virtual_BCU_12 ,NC        ,100,1,Yes          ,Alarm_Event_Node,,,,<br />
,,,,,,,,,,,,,<br />
//================================================================================,,,,,,,,,,,,,<br />
//,,,,,,,,,,,,,<br />
//    Server Side Map Descriptors,,,,,,,,,,,,,<br />
//,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
//Map Descriptor for Event Notification,,,,,,,,,,,,,<br />
Map_Descriptors,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
,,,,,,,,,,,,,<br />
Map_Descriptors,,,,,,,,,,,,,<br />
Map_Descriptor_Name ,Data_Array_Name ,Data_Array_Offset ,Function ,Node_Name ,Data_Type ,Object_ID ,Input_Alarm_State ,Notification_Class ,Active_Text ,Inactive_Text,,,<br />
L1_SMK1,DA_Trb_01       ,0,Server   ,Virtual_BCU_12 ,BI        ,30000,1,BAC_NC_EST         ,Alarm       ,Normal,,,<br />
L1_SMK2,DA_Trb_01       ,1,Server   ,Virtual_BCU_12 ,BI        ,30001,1,BAC_NC_EST         ,Alarm       ,Normal,,,<br />
L1_SMK3,DA_Trb_01       ,2,Server   ,Virtual_BCU_12 ,BI,30002,1,BAC_NC_EST         ,Alarm       ,Normal,,,<br />
L1_SMK4,DA_Trb_01       ,3,Server   ,Virtual_BCU_12 ,BI,30003,1,BAC_NC_EST         ,Alarm       ,Normal,,,<br />
</code></p>
]]></content:encoded>
	</item>
	<item>
		<title>By: BACnet BIBB&#8217;s at Chipkin Automation Systems - Articles</title>
		<link>http://www.chipkin.com/articles/bacnet-bibbs-table-bacnet-interoperability-building-blocks/comment-page-1#comment-808</link>
		<dc:creator>BACnet BIBB&#8217;s at Chipkin Automation Systems - Articles</dc:creator>
		<pubDate>Wed, 04 Feb 2009 00:15:57 +0000</pubDate>
		<guid isPermaLink="false">http://www.chipkin.com/articles/?p=243#comment-808</guid>
		<description>[...] &#171; BACnet BIBB&#8217;s TABLE - Bacnet Interoperability Building Blocks [...]</description>
		<content:encoded><![CDATA[<p>[...] &laquo; BACnet BIBB&#8217;s TABLE &#8211; Bacnet Interoperability Building Blocks [...]</p>
]]></content:encoded>
	</item>
</channel>
</rss>