BACnet Architecture

BACnet has an interesting architecture that all developers should know about for the effective operation of such building automation devices. The BACnet architecture is predominately limited to HVAC, lighting controls, and gateways.

BACnet emphasizes efficient, lightweight communication and optimized for small networks, small inter-networks, and short messages.

BACnet consists of a collapsed architecture that corresponds to four layers of the Open Systems Interconnection (OSI) model. The seven layer reference model is an international standard for conceptualizing network communication protocols and is widely used as the basis of many data communications standards.

The four layers from the OSI model within the BACnet architecture includes:

  • Application
  • Network
  • Data Link
  • Physical

Since BACnet is a non-connection protocol, the need for message segmentation and end-to-end error checking is much less than in a connection-based protocol. Thus, the overhead of a discrete transport layer is not justified and the functions normally in a transport layer are delegated to the application layer. In addition, the session layer is not needed, and since BACnet uses a fixed encoding scheme and offloads security to the application layer, a separate presentation layer is not needed.

The following figure from the standard examines the basic structure of the OSI model:

screen1.gif

Figure 1. Basic OSI Structure.

The next figure from the standard will present the BACnet architecture with the equivalent OSI layers to the developer:

 

screen2.gif

Figure 2. BACnet Architecture.The collapsed architecture was chosen due to the specific features and requirements of BAC networks, including a requirement that the protocol overhead be minimized as much as possible.

BAC networks are local area networks (LAN). This is true even though in some applications it is necessary to exchange information with devices in a building that is very far away. The long-distance communication is done through telephone networks. The routing, relaying, and guaranteed delivery issues are handled by the telephone system and can be considered external to the BAC network.

BAC devices are static. They don’t move from place to place and the functions that they are asked to perform do not change in the sense that a manufacturing device may make one kind of part today and some very different part tomorrow.

BACnet defines a protocol optimized for reliable and brief object messaging on a LAN. Based on the OSI model, BACnet is readily extended to many domains outside of the building automation and control networks for which it was originally intended, such as management applications and embedded control. In many of these applications, a specific part of BACnet can be applied with great benefit.

All developers should maintain an understanding of the BACnet architecture, especially when selecting devices for building automation applications.

Written by: Scott Cosby

© Chipkin Automation Systems 2007

Did you like this post?

Subscribe To The RSS Feed!
To catch many more articles like this in the future, make it easy on yourself and subscribe to me via RSS. You will not regret it!

Do you have a question?
We will do our best to try and solve any building automation, protocol, integration problem you may have

1 Response to “BACnet Architecture”


  1. 1 Amod Mujumdar Feb 23rd, 2009 at 2:40 am

    Dear Scott

    It is a nice brief on bacnet.

    We Crystaline Infotek based in INDIA at Pune. We are solution providers in home security domain. In one of our projects we need to give BACNET interface.
    Can you guide us to get details of bacnet protocol.

    Can we implement entire protocol in our host controller (PIC 18F series )
    Does this protocol has constraint of 32 bit archteure ? or can it be done in 8 bit also.?
    We got some info on LC3020 . Can this be used to develop system around bacnet ?

    Can you provide details of LC3020?

    Thanks & Best Regards
    Amod

Leave a Reply



Pages