RFC 2616 Fielding, et al.
2 Notational Conventions and Generic Grammar
2.1 Augmented BNF
All of the mechanisms specified in this document are described in both prose and an augmented Backus-Naur Form (BNF) similar to that used by RFC 822 [9]. Implementors will need to be familiar with the notation in order to understand this specification. The augmented BNF includes the following constructs:
- name = definition
- The name of a rule is simply the name itself (without any enclosing "<" and ">") and is separated from its definition by the equal "=" character. White space is only significant in that indentation of continuation lines is used to indicate a rule definition that spans more than one line. Certain basic rules are in uppercase, such as SP, LWS, HT, CRLF, DIGIT, ALPHA, etc. Angle brackets are used within definitions whenever their presence will facilitate discerning the use of rule names.
- "literal"
- Quotation marks surround literal text. Unless stated otherwise, the text is case-insensitive.
- rule1 | rule2
- Elements separated by a bar ("|") are alternatives, e.g., "yes | no" will accept yes or no.
- (rule1 rule2)
- Elements enclosed in parentheses are treated as a single element. Thus, "(elem (foo | bar) elem)" allows the token sequences "elem foo elem" and "elem bar elem".
- *rule
- The character "*" preceding an element indicates repetition. The full form is "<n>*<m>element" indicating at least <n> and at most <m> occurrences of element. Default values are 0 and infinity so that "*(element)" allows any number, including zero; "1*element" requires at least one; and "1*2element" allows one or two.
- [rule]
- Square brackets enclose optional elements; "[foo bar]" is equivalent to "*1(foo bar)".
- N rule
- Specific repetition: "<n>(element)" is equivalent to "<n>*<n>(element)"; that is, exactly <n> occurrences of (element). Thus 2DIGIT is a 2-digit number, and 3ALPHA is a string of three alphabetic characters.
- #rule
- A construct "#" is defined, similar to "*", for defining lists of
elements. The full form is "<n>#<m>element" indicating at least
<n> and at most <m> elements, each separated by one or more commas
(",") and OPTIONAL linear white space (LWS). This makes the usual
form of lists very easy; a rule such as
( *LWS element *( *LWS "," *LWS element ))
can be shown as1#element
Wherever this construct is used, null elements are allowed, but do not contribute to the count of elements present. That is, "(element), , (element) " is permitted, but counts as only two elements. Therefore, where at least one element is required, at least one non-null element MUST be present. Default values are 0 and infinity so that "#element" allows any number, including zero; "1#element" requires at least one; and "1#2element" allows one or two. - ; comment
- A semi-colon, set off some distance to the right of rule text, starts a comment that continues to the end of line. This is a simple way of including useful notes in parallel with the specifications.
- implied *LWS
- The grammar described by this specification is word-based. Except where noted otherwise, linear white space (LWS) can be included between any two adjacent words (token or quoted-string), and between adjacent words and separators, without changing the interpretation of a field. At least one delimiter (LWS and/or
- separators) MUST exist between any two tokens (for the definition of "token" below), since they would otherwise be interpreted as a single token.
2.2 Basic Rules
The following rules are used throughout this specification to describe basic parsing constructs. The US-ASCII coded character set is defined by ANSI X3.4-1986 [21].
OCTET = <any 8-bit sequence of data>
CHAR = <any US-ASCII character (octets 0 - 127)>
UPALPHA = <any US-ASCII uppercase letter "A".."Z">
LOALPHA = <any US-ASCII lowercase letter "a".."z">
ALPHA = UPALPHA | LOALPHA
DIGIT = <any US-ASCII digit "0".."9">
CTL = <any US-ASCII control character
(octets 0 - 31) and DEL (127)>
CR = <US-ASCII CR, carriage return (13)>
LF = <US-ASCII LF, linefeed (10)>
SP = <US-ASCII SP, space (32)>
HT = <US-ASCII HT, horizontal-tab (9)>
<"> = <US-ASCII double-quote mark (34)>
HTTP/1.1 defines the sequence CR LF as the end-of-line marker for all protocol elements except the entity-body (see appendix 19.3 for tolerant applications). The end-of-line marker within an entity-body is defined by its associated media type, as described in section 3.7.
CRLF = CR LF
HTTP/1.1 header field values can be folded onto multiple lines if the continuation line begins with a space or horizontal tab. All linear white space, including folding, has the same semantics as SP. A recipient MAY replace any linear white space with a single SP before interpreting the field value or forwarding the message downstream.
LWS = [CRLF] 1*( SP | HT )
The TEXT rule is only used for descriptive field contents and values that are not intended to be interpreted by the message parser. Words of *TEXT MAY contain characters from character sets other than ISO- 8859-1 [22] only when encoded according to the rules of RFC 2047 [14].
TEXT = <any OCTET except CTLs,
but including LWS>
A CRLF is allowed in the definition of TEXT only as part of a header field continuation. It is expected that the folding LWS will be replaced with a single SP before interpretation of the TEXT value.
Hexadecimal numeric characters are used in several protocol elements.
HEX = "A" | "B" | "C" | "D" | "E" | "F"
| "a" | "b" | "c" | "d" | "e" | "f" | DIGIT
Many HTTP/1.1 header field values consist of words separated by LWS or special characters. These special characters MUST be in a quoted string to be used within a parameter value (as defined in section 3.6).
token = 1*<any CHAR except CTLs or separators>
separators = "(" | ")" | "<" | ">" | "@"
| "," | ";" | ":" | "\" | <">
| "/" | "[" | "]" | "?" | "="
| "{" | "}" | SP | HT
Comments can be included in some HTTP header fields by surrounding the comment text with parentheses. Comments are only allowed in fields containing "comment" as part of their field value definition. In all other fields, parentheses are considered part of the field value.
comment = "(" *( ctext | quoted-pair | comment ) ")"
ctext = <any TEXT excluding "(" and ")">
A string of text is parsed as a single word if it is quoted using double-quote marks.
quoted-string = ( <"> *(qdtext | quoted-pair ) <"> )
qdtext = <any TEXT except <">>
The backslash character ("\") MAY be used as a single-character quoting mechanism only within quoted-string and comment constructs.
quoted-pair = "\" CHAR