Chipkin Automation Systems has developed a FieldServer driver which communicates with Mitsubishi's CHC Air Conditioning Controller. The driver can read process/status information and can send commands and setpoints. Combining this driver with any of the other FieldServer drivers allows you to easily transfer data between:

Web
  • Webserver
Building automation
  • Lonworks
  • BACnet
  • Metasys N2
Industial
  • Scada / HMI
  • Modbus (Full family of protocols)
  • Rockwell (Full family of protocols)
  • GE-Fanuc (Full family of protocols)
  • Siemen
  • Omron
  • DNP3
  • Opto22
  • Profibus
Fire Alarm Panels
  • Notifier AM200,300,400,600
  • Notifier 1010/2020
  • Simplex 4100
  • Siemens Cerberus MXL
  • Grinnell
  • Fike Cheetah
  • Vesda
HVAC Systems
  • Strane BCU and Summit
  • WorkStation
  • Alerton
  • Delta Controls
  • Andover Controls
  • Siemens
  • Honeywell and Automation Logic
  • DataAire
  • TekAir
  • York Chillers
  • McQuay
  • Carrier
Others
  • Catterpillar
  • Lutron
... Over 110 other protocols and counting



FieldServer Driver
FS87xx-yy
MITSUBISHI CHC-MF

Description


This driver is used to exchange data between a FieldServer and a Mitsubishi Heavy Industries communication interface known as a CHC-MF.

The driver is a serial driver using a RS232 serial port to connect between the FieldServer and the CHC-MF. An RS485 port together with a converter can also be used for the connection.

The driver provides client and server functionality.

As a client the driver can poll for data from Air Conditioning Units via the CHC-MF interface as well as writing some control and set points.

Server functionality is provided only to support our ongoing quality assurance program by facilitating automated testing of the driver. It is not documented or supported. If required please contact the FST sales group to discuss your requirements.

Fieldserver Mode Nodes Comments
Client 1 A maximum of 1 Mitsubishi CHC-MF device per FieldServer Port.
Server 1 A maximum of 1 Mitsubishi CHC-MF device per FieldServer Port.



Formal Driver Type

  • Serial
  • Client or Server



Compatibility Matrix


FieldServer Model Compatible with this driver
FS-x2010 Yes, No
FS-x2011 Yes, No
FS-x40 Yes, No



Connection Information


Connection type: EIA232
Baud Rates: Driver Supports : 110; 300; 600; 1200; 2400; 4800; 9600; 19200; 28800; 38400; 57600; 115200 Baud
Vendor Equipment Supports : 4800 Baud
Data Bits: Driver Supports : 7,8
Vendor Equipment Supports : 7
Stop Bits: Driver Supports : 1,2
Vendor Equipment Supports: 1
Parity: Driver Supports : Odd, Even, None
Hardware interface: N/A
Multidrop Capability No



Devices Tested


Device Tested (FACTORY, SITE)
This driver has not been field or factory tested against any devices.

Call Chipkin Automation Systems for an update on this information.



Connection Configurations





Connection Notes


Vendor information on the specific connection/terminals/D-Type connector to be found on the CHC-MF is yet to be determined.




Communications Functions - Supported functions at a glance:


Read/Write Operations supported


FieldServer as a Client FieldServer as a Server
Start / Stop Operation Digital Start/Stop Response
One Point Request Digital Start/Stop Point
Parameter Setting Operation Start / Stop Operation
Initial Data Request Processing System Clock Time Notification
Forced Shutdown in a Fire Analog Point Response
Parameter Point Response
Add Up Point Response
Completion of parameter Setting operation

When the connection is first opened to the CHC unit or when the driver is recovering a connection (after a loss of connection) then the driver will wait for an Initial Data Request and respond appropriately. Thereafter, normal polling will occur. In the event that the driver does not receive the Initial Data Request from the CHC within a specified time it will default to normal polling behavior.




Data Points


The FieldServer reads data from the ICSII device. The data points below are the points available to the FieldServer but this does not necessarily mean that they are valid for the HVAC device connected to the ICSII.


Point Number Point Read/ Write
1 Start/Stop RW
2 Temp. Setting R
3 Automatic temperature control mode setting RW
4 Temperature control mode setting RW
5 Room Temperature R
6 Remote control mode, setting 1 RW
7 Remote control mode, setting 2 RW
8 Remote control mode, setting 3 RW
9 Filter sign reset RW
10 Forced Thermo off RW
20 Electrical Energy R



Configuration


The driver can be configured to read everything with a "single line" configuration. Data will be read and stored in Data Arrays at fixed locations. Alternatively, the driver can be configured to read one/more single data points and have the data stored in any location.


 
0.002229